C. REMOVING BLOWER MOTOR
(Figures 12 (Top View) and 13).
(1) Remove screw securing the stay.
(2) Disconnect all lead wires from the Blower Motor
and H.V. Capacitor.
(3) Remove 2 screws securing the Blower Base and
disengage 3 hooks from the Rear Plate of Cavity
(Figure 13).
(4) Remove 1 screw securing the Blower Motor with
the Blower Base.
D. REMOVING MAGNETRON
(Figure 12
(
Top View
)
)
After removing the Blower Motor :
(1) Remove Duct (mag. exhaust). Remove the screw
securing the stay.
(2) Remove 1 screw securing the Thermal Protector.
(3) Disconnect 2 lead wires from the Magnetron.
(4) Remove 4 screws securing the Magnetron to the
Waveguide.
(5) Take out Magnetron VERY CAREFULLY.
NOTE
1.
When removing the Magnetron from the Cavity or
Waveguide, use a proper care so that the dome of
the Magnetron does not hit any adjacent parts of
Microwave Oven.
2.
Make sure that the contact face of the Magnetron
Gasket is free from any damage or deformation.
3.
Adjust the position of the Magnetron properly, so
that it correctly sits in place and the Magnetron
Gasket is in contact with the mounting rim evenly.
4.
While holding the Magnetron under this condition,
tighten mounting screws or nuts with your fingers
temporarily.
5.
Further tighten the screws or nuts with a box
wrench, giving one or two turns to each of the
screws (or nuts) alternatively so that the Magnetron
is mounted onto the bracket uniformly.
6.
After replacing the Magnetron, be sure to check the
microwave energy leakage with a leakage detector
and confirm the leakage is below 5mW/cm
2
.
- 12 -
Duct (mag. exhaust)
Thermal Protector
Blower Base
Screw
Duct (mag. intake)
Stay
Figure 12 (Top View)
Figure 13
Hooks
Blower Motor
Screws
Содержание EM-V3410WS