System Design
7. Center-of-gravity and earthquake resistance
D-34
c) Bo
ttom su
rfac
e of n
ormal c
eilin
g slab, co
ncre
te w
all su
rface
Long-t
erm a
llo
wabl
e pul
l-ou
t l
oad (N)
Not
es
1.
Thes
e a
re s
ho
rt-
te
rm al
lo
wa
bl
e p
ul
l-o
ut
loads
fo
r b
ol
ts
embed
de
d
as
s
hown i
n t
he
di
ag
ram
abov
e.
2.
The c
onc
re
te
des
ig
n c
har
ac
te
ris
tic
s
trengt
h i
s t
ak
en t
o be F
C
=
17.
6 N/
mm
2
.
3.
W
he
n t
he di
m
ens
io
ns
di
ffe
r f
rom
t
he abov
e d
iag
ram,
o
r i
f t
he
conc
ret
e
des
ig
n c
ha
rac
te
ris
tic
s
tre
ngt
h
di
ffe
rs
, t
hen t
he p
ul
l-out
load c
an b
e c
al
cul
at
ed ac
co
rdi
ng wi
th
t
he f
ormul
ae
f
or bol
ts
in
a
st
rong f
oun
dat
ion,
at
th
e l
eft, an
d
di
vid
e the
re
su
lt b
y 1
.5
to
ob
ta
in
the al
lo
wa
bl
e
pul
l-o
ut
lo
ad
.
In
any
c
as
e,
the al
lo
wa
bl
e p
ul
l-out
lo
ad
on on
e b
ol
t mus
t not
ex
ce
ed
7,
840
N.
4.
It i
s
de
si
rabl
e t
hat
L
≥
6d
.
The
condi
tion
s i
ndi
ca
ted b
y “-” i
n
th
e
abov
e t
abl
e s
houl
d
be
a
voi
ded
.
5.
It is
ne
ce
ss
ary t
o i
nv
est
ig
at
e
ite
m
b
), t
he
s
hor
t-t
er
m
pul
l-ou
t l
oad
of
normal
s
upports
w
ith
regard t
o eart
hquak
es
when
the
supports are
in
st
al
led
in
t
he
bott
om o
f
ce
ili
ng
sl
abs
and on
c
on
cre
te
wal
ls
des
igned
to
s
upport heavy obj
ec
ts.
6.
If
ty
pe 1
or 2
li
gh
twei
gh
t c
on
cret
e is us
ed
, a
llo
w
10%
marg
in
.
b)
U
ppe
r s
ur
fa
ce
of
no
rm
al
fl
oo
r s
lab
S
hort
-te
rm
pul
l-ou
t l
oad
(N)
Not
es
1.
The
se are
short
-te
rm all
owabl
e p
ul
l-out
load
s
fo
r bolts
embedded
as
s
hown
in
th
e di
agram
abo
ve
.
2.
The
c
onc
re
te
de
si
gn
c
haract
eris
tic
st
reng
th
is t
ak
en
to
be
F
C
= 1
7.
6
N/
m
m
2
.
3.
W
hen t
he
di
men
si
on
s d
iff
er f
ro
m
t
he abo
ve
di
agram
, or if
t
he
co
nc
ret
e de
si
gn
c
haract
eris
tic
s
treng
th dif
fe
rs
, t
hen
th
e pu
ll-
out l
oad
can be
c
alc
ul
at
ed a
cc
ordi
ng w
ith
t
he
f
or
m
ul
ae
fo
r bo
lts i
n a
s
trong
foundat
io
n,
a
t t
he
le
ft.
In
an
y cas
e,
t
he al
lo
wab
le pul
l-ou
t l
oad on
one bol
t must
no
t exceed
11,
760
N.
4.
It is desi
rabl
e t
ha
t L
≥
6d
. The
condi
tion
s i
ndic
at
ed
by “-”
i
n
th
e
abov
e t
abl
e s
houl
d
be
a
voi
ded
.
5.
If
ty
pe 1
or 2
li
gh
twei
gh
t c
on
cret
e is us
ed
, a
llo
w
10%
marg
in
.
Ins
tal
lat
ion
lo
ca
tion:
a) S
ol
id f
ou
nda
tio
n
S
hort
-t
erm al
lo
wabl
e pul
l-o
ut
load o
f a bol
t i
s obt
ai
ned wi
th
the
fo
llo
w
in
g
fo
rm
ul
ae
. Howev
er,
if
th
e
shear st
ress on
the bo
lt e
xc
eed
s
44.
1 N
/m
m
2
(for
S
S
400)
, bo
lt st
rength and a
ss
uranc
e t
ha
t al
lo
wabl
e
tensi
le
st
ress is
no
t e
xc
eeded
mu
st
b
e v
erif
ied
.
T
a =
π・
d
・
・
fc
…
(a)
W
here,
Ta
=
A
nc
hor bolt al
lo
wabl
e
sh
or
t-t
erm
pul
l-ou
t l
oad (N)
d = A
nc
hor bol
t n
omi
na
l di
amet
er (mm
)
=
E
m
bedded
lengt
h of an
chor
bol
t (m
m).
(the l
eng
th
fr
om
20
mm
bel
ow
th
e s
ur
fac
e of
the
co
nc
ret
e f
ounda
tion
.)
fc =
shor
t-t
er
m
all
owabl
e bond
st
res
s i
n rei
nf
orc
ed
c
onc
re
te
fc =
F
C
(fr
om
“S
ta
nd
ar
d f
or R
C
s
truc
tur
es
d
es
ign,
” pu
bl
is
he
d
by
th
e
A
rc
hi
tec
tu
ra
l I
ns
tit
ut
e
of
J
apa
n)
F
C
= Conc
ret
e des
ign c
ha
rac
te
ris
tic
s
trengt
h (
N
/m
m
2
)
(N
or
m
all
y,
1
7.
6 N
/m
m
2
is us
ed
.)
For anc
hor bo
lts
po
si
tioned i
n t
he
co
rner or near t
he
edge of
t
he
foundat
io
n,
th
e s
hort
-te
rm
all
owabl
e pul
l-out
load
s
hal
l be
ta
ke
n t
o
be
the
mi
nimum
of
the
va
lu
es
fr
om
fo
rm
ul
ae (b) be
lo
w, and (a).
T
a =
6
π・
C
2
・
p
…
(b)
W
here C
=
th
e dist
anc
e
from
the edg
e of
th
e f
ounda
tion
to
th
e c
en
te
r
of
the bo
lt (m
m)
Howev
er
, C
≥
4
d, a
nd
C
-
≥
50
mm
p
=
Corre
ct
ion f
act
or f
or c
on
cret
e
de
si
gn s
treng
th
is
P
=
M
in
, 0
.4
9 +
Not
es
1.
L
s
hou
ld
be
≥
6d
(where d
= no
minal
an
chor bolt di
ame
ter).
2.
If
ty
pe
1 or
2 li
ght
we
ight c
onc
re
te
is
u
sed
, all
ow 10
%
margi
n.
200
6370
7938
9506
11760
11760
11760
160
180
5586
6958
8330
11172
11760
-
140
150
4312
5390
6566
8722
-
-
110
C
on
cr
ete
th
ic
kn
es
s (
m
m
)
120
3136
3920
4704
-
-
-
80
B
ol
t di
am
et
er
d (nomi
na
l)
M 8
M10
M12
M16
M20
M24
E
ffe
ct
iv
e embedded
lengt
h (
) (
mm)
200
4214
5292
6272
7840
7840
7840
160
180
3724
4606
5488
7448
7840
-
140
150
2842
3528
4312
5782
-
-
110
C
on
cr
ete
th
ic
kn
es
s (
m
m
)
120
2058
2548
3136
-
-
-
80
B
ol
t di
ame
ter
d (nomi
nal
)
M 8
M10
M12
M16
M20
M24
E
ffe
ct
iv
e embedded
lengt
h (
) (
mm)
9 100
d 2
Fc
30
Fc
100
1 6
(2
) Al
low
abl
e
pul
l-ou
t l
oad
of
em
bed
ded
L
- and
L
A
-ty
pe b
olt
s
Содержание ECO G SGP-EW120M2G2W
Страница 3: ...A 1 System Configuration Contents 1 Type Configuration 1 Outdoor unit A 2 ...
Страница 12: ...Outdoor Unit 3 External Dimensions B 8 ...
Страница 13: ...Outdoor Unit 4 Wiring Diagram B 9 ...
Страница 14: ...Outdoor Unit 5 Performance Characteristics B 10 Cooling Heating SGP EW120M2G2W ...
Страница 15: ...Outdoor Unit 5 Performance Characteristics B 11 Cooling Heating SGP EW150M2G2W ...
Страница 16: ...Outdoor Unit 5 Performance Characteristics B 12 Cooling Heating SGP EW190M2G2W ...
Страница 17: ...Outdoor Unit 5 Performance Characteristics B 13 Cooling Heating SGP EW240M2G2W ...
Страница 18: ...Outdoor Unit 6 Operating Sound Level Characteristics B 14 1 Standard Mode ...
Страница 19: ...Outdoor Unit 6 Operating Sound Level Characteristics B 15 ...
Страница 20: ...Outdoor Unit 6 Operating Sound Level Characteristics B 16 ...
Страница 21: ...Outdoor Unit 6 Operating Sound Level Characteristics B 17 ...
Страница 22: ...Outdoor Unit 6 Operating Sound Level Characteristics B 18 2 Quiet Mode ...
Страница 23: ...Outdoor Unit 6 Operating Sound Level Characteristics B 19 ...
Страница 24: ...Outdoor Unit 6 Operating Sound Level Characteristics B 20 ...
Страница 25: ...Outdoor Unit 6 Operating Sound Level Characteristics B 21 ...
Страница 28: ...Control Related 1 System Block Diagram C 2 ...
Страница 29: ...Control Related 2 Remote Control Warning List C 3 ...
Страница 30: ...Control Related 2 Remote Control Warning List C 4 ...
Страница 31: ...Control Related 2 Remote Control Warning List C 5 ...
Страница 38: ...System Design 3 Refrigerant piping design D 7 2 Selecting system header and branch piping sizes ...
Страница 75: ...Installation Work 1 Points regarding refrigerant pipe work E 2 1 Points regarding branch pipe work APR P160BG ...
Страница 76: ...Installation Work 1 Points regarding refrigerant pipe work E 3 APR P680BG ...
Страница 77: ...Installation Work 1 Points regarding refrigerant pipe work E 4 APR P1350BG ...
Страница 78: ...Installation Work 1 Points regarding refrigerant pipe work E 5 APR CHP680BG APR CHP1350BG ...
Страница 83: ...Installation Work 2 Points regarding electrical work outdoor unit E 10 1 Wiring thickness and device capacity ...
Страница 85: ...Installation Work 2 Points regarding electrical work outdoor unit E 12 3 Precautions regarding electrical work ...
Страница 86: ...Installation Work 2 Points regarding electrical work outdoor unit E 13 ...
Страница 87: ...Installation Work 3 Outdoor unit installation work E 14 ...
Страница 88: ...Installation Work 3 Outdoor unit installation work E 15 ...
Страница 89: ...Installation Work 3 Outdoor unit installation work E 16 ...
Страница 90: ...Installation Work 3 Outdoor unit installation work E 17 ...
Страница 91: ...Installation Work 3 Outdoor unit installation work E 18 ...
Страница 92: ...Installation Work 3 Outdoor unit installation work E 19 ...
Страница 93: ...Installation Work 3 Outdoor unit installation work E 20 ...
Страница 94: ...Installation Work 3 Outdoor unit installation work E 21 ...
Страница 95: ...Installation Work 3 Outdoor unit installation work E 22 ...
Страница 96: ...Installation Work 3 Outdoor unit installation work E 23 ...
Страница 97: ...Installation Work 3 Outdoor unit installation work E 24 ...
Страница 98: ...Installation Work 3 Outdoor unit installation work E 25 ...
Страница 99: ...Installation Work 3 Outdoor unit installation work E 26 ...
Страница 100: ...Installation Work 3 Outdoor unit installation work E 27 ...
Страница 101: ...Installation Work 3 Outdoor unit installation work E 28 ...
Страница 102: ...Installation Work 3 Outdoor unit installation work E 29 ...
Страница 103: ...Installation Work 3 Outdoor unit installation work E 30 ...
Страница 104: ...Installation Work 3 Outdoor unit installation work E 31 ...
Страница 105: ...Installation Work 3 Outdoor unit installation work E 32 ...
Страница 106: ...Installation Work 3 Outdoor unit installation work E 33 ...
Страница 107: ...F 1 Separately Sold Parts Contents 1 Outdoor unit related parts 1 Exhaust extension kit SGP PEX560K F 2 ...