800 A
External Wiring Diagram
(7)
(E)
L2(S)
L3(T)
L1(R)
RB1 RB2
-DC
+DC
+DC
-DC
CN10
(8)
(7)
MC1
MC1
MC
W2
V2
U2
V2
W2
U2
R
S
T
SH
SH
(5)
W1
V1
U1
V1
W1
U1
(E)
+24 V
0 V
+24 V
0 V
(13)
SH SH
CN10
User unit
(2)
TB
TB
TB
TB
User unit
TB
TB
TB
TB
(3)
MC3
(3)
MC2
(4)
+12 V
-12 V
MC3
TH1-1
TH1-2
DB1
DB2
TB
MC2
IN/OUT
1
2
CONT1+
CONT1-
4
5
8
7
6
3
CONT2-
CONT2+
SH
6
5
8
3
4
EDM+
HWGOFF1-
HWGOFF2-
SH
24 VDC
(11)
24 VDC
CN4
EDM-
SH
3
4
5
6
(9)
(14)
(11)
7
16
OUT1+
OUT1-
17
CN2
OUT2-
OUT2+
19
18
CONT4-
10
CONT3-
CONT4+
9
8
CONT3+
7
CONT6-
15
CONT6+
CONT5-
14
12
CONT5+
11
20
21
22
23
24
(10)
2
1
SG
13
26
25
CONT7+
CONT7-
5 to 24 VDC
(11)
(19)
1
2
CN3
1
2
1
RXD+
RXD-
TXD+
TXD-
EN1/EN2
(16)
(17)
(18)
For Safety models and
Safe Torque Off models only
(10)
Reserved
(Do not connect)
(15)
For tandem operation
Servo motor
Encoder
Shielding
Shielding
Shielding
Lithium battery 3.6 VDC
Ethernet I/O
General-purpose output
General-purpose input
Reserved
(Do not connect)
Encoder battery input
System error
Start ready
ON
AC power 3ø
380 to 480 V
50/60 Hz
Emergency
stop
24 VDC
power supply
External regenerative
resistor
Connect to TH1-1
and TH1-2.
Connect to TH1-1
and TH1-2.
Dynamic brake resistor
Dynamic brake resistor
Amplifier unit
Power
supply
unit
Start ready
OFF
Motor thermostat or
motor fan thermostat
Thermal
Fan
For dynamic braking
DB resistor thermostat, motor thermostat,
or motor fan thermostat
(1) [
] The part indicated by the figure on the left should be wired with shielded
twisted pair (STP) cables.
(2) An external regenerative resistor should be connected between the RB1 and RB2 terminals.
(3) Consult us when selecting an external dynamic brake resistor.
(4) Motor side connections vary depending on motor specifications. Perform connections
according to the specifications.
(5) Refer to the encoder connection diagram for the wiring of encoder connectors.
(6) R, S, T, +DC, -DC, RB1, RB2, U1, V1, W1, U2, V2, and W2 are high-voltage circuits. All
other signal lines are low-voltage circuits. When wiring, provide sufficient clearance
between high-voltage and low-voltage circuits.
(7) Ground with a wire of 5.5 mm
2
or larger size.
(8) The amplifier does not have a built-in dynamic brake circuit. DB1 and DB2 are DB
timing outputs, and TH1-1 and TH1-2 are DB resistor thermostat inputs. When not
using a thermostat, ensure that TH1-1 and TH1-2 are short-circuited. Necessary items,
an electromagnetic contactor, resistor, power supply, and cable, are to be prepared by
the customer. For the electromagnetic contactor, prepare one that works with DC
power. Relay contact rating: 30 VDC, 2 A (cosø = 0.4, L/R = 7 ms)
(9) Use a shielded twisted pair (STP) cable of Category 5e or higher (TIA).
(10) Do not connect anything to the CN4-1, CN4-2, CN2-20, or CN2-21 pins.
(11) An external power supply is to be prepared by the customer.
(12) Consult us when conducting a withstand voltage test.
(13) For the wiring of unit-to-unit cables, refer to the wiring diagram in the Instruction
Manual (M0011694).
(14) CN4 is a connector for the Safe Torque Off function. Turning Servo ON (motor in
operation) requires to connect a safety device to CN4 and get STO enabled. When
not using STO, be sure to insert the short-circuiting STO connector (Mfr. part no.:
1971153-2) to CN4.
(15) The CN2-20 to CN2-25 pins are used for tandem operation.
Connect compatible amplifiers as on the right.
22
23
24
25
22
23
24
25
(16) When using an incremental encoder to configure a semi-closed system, connect
it to EN2.
(17) Use of a UL or IEC/EN compliant leakage circuit breaker is recommended.
(18) For a 24 VDC power supply, use a SELV (safety extra low voltage) power supply
with reinforced insulation on I/O terminals.
(19) No wiring is required when using the battery-less absolute encoder.
Connector
No.
Name
Housing, plug, shell
EN1/
EN2
Encoder connector 54599-1016
CN2
General-purpose
I/O connector
Connector: HDR-
Shell kit: HDR-E26LPH
CN4
STO connector
For short-circuiting: 1971153-2
For wiring: 2013595-3
52
Servo Amplifiers
R 3E Model EtherCAT Interface type