Connector no.
Description
Model no.
Manufacturer part no.
Manufacturer
CN1
Controller connection
AL-00385594
10150-3000PE and 10350-52A0-008
3M Japan Limited
EN1
Encoder connection
AL-00632607
36210-0100PL and 36310-3200-008
EN2
Encoder connection
AL-00632607
36210-0100PL and 36310-3200-008
CN4
(1)
Safety device connection
(for short-circuiting)
AL-00718251-01
2040978-1
Tyco Electronics
Japan G.K.
CN4
Safety device connection
(for wiring)
AL-00718252-01
2013595-3
CNA
(2)
Main circuit power supply
connection
AL-00953863-01
03JFAT-SAXGDK-P15
J.S.T.
CNB
(2)
Servo motor connection
AL-00953865-01
03JFAT-SAZGDK-P15
CNC
(2)
Regenerative resistor
connection
AL-00953864-01
03JFAT-SAYGDK-P15
Connector tool For CNA, CNB, and CNC
AL-00953866-01
J-FAT-OT-P
CND
(2)
Control circuit power supply
connection
AL-00961843-01
04JFAT-SAGG-G-KK
Connector tool For CND
AL-00961844-01
J-FAT-OT(N)
CNE
Holding brake power output
AL-00953867-01
02MJFAT-SAGF
Connector tool For CNE
AL-00953868-01
MJFAT-OT
SF-CN1
Safety device connection (for
functional safety models only)
AL-Y0012189-01
DFMC 0,5/10-ST-2,54
Phoenix
Contact K.K.
SF-CN2
Safety device connection (for
functional safety models only)
AL-Y0012189-01
DFMC 0,5/10-ST-2,54
(1) When CN4 is not used, be sure to buy and insert the (short-circuiting) safety device connector to CN4 on the servo amplifier.
(2) Servo amplifiers come with one piece of each CNA, CNB, CNC, and CND.
Individual connectors
Connector sets (for non-STO models)
Connector set no.
AL-00723290
AL-00966991
AL-00966993
AL-00966995
Connectors
included in the set
CN1: Controller connection
EN1: Encoder connection
EN2: Encoder connection
–
–
CNE: Holding brake connection
–
–
Connector tool for CNE
–
–
Remarks
For fully closed-loop systems
Connector sets (for STO models)
Connector set no.
AL-00723159
AL-00967013
AL-00967015
AL-00967017
Connectors
included in the set
CN1: Controller connection
EN1: Encoder connection
EN2: Encoder connection
–
–
CN4: Safety device connection
(for wiring)
CNE: Holding brake connection
–
–
Connector tool for CNE
–
–
Remarks
For fully closed-loop systems
■
Analog/Pulse input type
25 to 100 A
Servo Amplifier Connectors
104
Options