Standard Model Number List
Contact us for specifications of models that are not listed.
Input voltage
400 VAC
Servo Amplifier
R 3E Model Analog/Pulse Input Type
Main circuit
power supply
Control circuit
power supply
Encoder
type
General-purpose
output
Internal
regenerative
resistor
STO function
(1)
Safety
(2)
Amplifier
capacity
Model no.
Page
Specifications Dimensions
400 VAC class
380 to 480 VAC
3-phase
24 VDC
Absolute
encoder
Sinking type
(NPN)
–
–
25 A
RS3C02A0AA0
p. 26
p. 28
50 A
RS3C05A0AA0
p. 26
p. 28
100 A
RS3C10A0AA0
p. 26
p. 28
–
150 A
RS3C15A0AL0
p. 26
p. 29
300 A
RS3C30A0AM0
p. 26
p. 29
800 A
RS3D80A0AM0
p. 26
p. 30
(Without delay
circuit)
–
25 A
RS3C02A0AA2
p. 26
p. 28
50 A
RS3C05A0AA2
p. 26
p. 28
100 A
RS3C10A0AA2
p. 26
p. 28
–
150 A
RS3C15A0AL2
p. 26
p. 29
300 A
RS3C30A0AM2
p. 26
p. 29
800 A
RS3D80A0AM2
p. 26
p. 30
(Without delay
circuit)
25 A
RS3C02A0AAC
p. 26, 78
p. 80
50 A
RS3C05A0AAC
p. 26, 78
p. 80
100 A
RS3C10A0AAC
p. 26, 78
p. 80
–
150 A
RS3C15A0ALC
p. 26, 78
p. 29
300 A
RS3C30A0AMC
p. 26, 78
p. 29
800 A
RS3D80A0AMC
p. 26, 78
p. 30
Sourcing type
(PNP)
–
–
25 A
RS3C02A0BA0
p. 26
p. 28
50 A
RS3C05A0BA0
p. 26
p. 28
100 A
RS3C10A0BA0
p. 26
p. 28
–
150 A
RS3C15A0BL0
p. 26
p. 29
300 A
RS3C30A0BM0
p. 26
p. 29
800 A
RS3D80A0BM0
p. 26
p. 30
(Without delay
circuit)
–
25 A
RS3C02A0BA2
p. 26
p. 28
50 A
RS3C05A0BA2
p. 26
p. 28
100 A
RS3C10A0BA2
p. 26
p. 28
–
150 A
RS3C15A0BL2
p. 26
p. 29
300 A
RS3C30A0BM2
p. 26
p. 29
800 A
RS3D80A0BM2
p. 26
p. 30
(Without delay
circuit)
25 A
RS3C02A0BAC
p. 26, 78
p. 80
50 A
RS3C05A0BAC
p. 26, 78
p. 80
100 A
RS3C10A0BAC
p. 26, 78
p. 80
–
150 A
RS3C15A0BLC
p. 26, 78
p. 29
300 A
RS3C30A0BMC
p. 26, 78
p. 29
800 A
RS3D80A0BMC
p. 26, 78
p. 30
Servo Amplifier
R 3E Model EtherCAT Interface Type
Main circuit
power supply
Control circuit
power supply
Encoder
type
General-purpose
output
Internal
regenerative
resistor
STO function
(1)
Safety
(2)
Amplifier
capacity
Model no.
Page
Specifications Dimensions
400 VAC class
380 to 480 VAC
3-phase
24 VDC
Absolute
encoder
Photo relay
output
(with delay
circuit)
–
25 A
RS3C02A2HA4
p. 46
p. 47
50 A
RS3C05A2HA4
p. 46
p. 47
100 A
RS3C10A2HA4
p. 46
p. 47
–
150 A
RS3C15A2HL4
p. 46
p. 48
300 A
RS3C30A2HM4
p. 46
p. 48
800 A
RS3D80A2HM4
p. 46
p. 49
(with delay
circuit)
25 A
RS3C02A2HAE
p. 46, 78
p. 80
50 A
RS3C05A2HAE
p. 46, 78
p. 80
100 A
RS3C10A2HAE
p. 46, 78
p. 80
–
150 A
RS3C15A2HLE
p. 46, 78
p. 48
300 A
RS3C30A2HME
p. 46, 78
p. 48
800 A
RS3D80A2HME
p. 46, 78
p. 49
Our servo amplifiers conform to UL, cUL, and EN standards and KC mark as standard.
(1) Safe Torque Off (STO) is a safety function defined in IEC/EN 61800-5-2:2016.
(2) In addition to STO,
(1)
also SS1 (Safe Stop 1), SS2 (Safe Stop 2), SOS (Safe Operating Stop), SLS (Safely-Limited Speed), SBC (Safe Brake Control), and SSM (Safe
Speed Monitor)
→
p. 78
14
Standard Model Number List