2-6
SAFETY
SY95C Excavator OMM
High-Pressure Oil Lines
WARNING
• Never perform inspections or replace items while
any system is under pressure. Working on a
system under pressure could lead to serious
injury.
• Never use your hands to check or feel for leaks.
Always wear personal protective equipment
(PPE), and use a piece of wood or cardboard to
check for leaks.
• If high-pressure fluids penetrate skin or get into
eyes, seek medical attention immediately.
Failure to follow these warnings can result in
death or serious injury.
Check for cracks in the lines or hoses and for swelling in
the hoses.
NOTE:
If there is any leakage from a line or hose, the
surrounding area may be wet or have an
accumulation of dust and dirt at the site of a leak.
Replace lines and hoses immediately if swelling,
cracking, or leaks are found or if failure occurs.
Accumulator
This machine is equipped with an accumulator charged
with high-pressure nitrogen gas. Do not disassemble the
accumulator.
Never expose the accumulator to temperatures over
140°F (60°C) or to open flames.
Never weld on the accumulator.
Never strike the accumulator.
If the accumulator needs service, contact a SANY dealer.
Electrical System
Always clean the electrical system using only
SANY-approved electrical cleaners.
Never use caustic soaps, high-pressure water, or steam
cleaners to clean the electrical system. These could
damage the system or cause intermittent system failures.
Battery Safety
When working with batteries, always work in a
well-ventilated area. Batteries present a hazard,
especially when they have been in use for a long period
of time. The following are some basic precautions for
working around batteries:
• Always wear personal protective equipment (PPE).
• Battery gases are extremely explosive. Smoking,
sparks, or open flames could cause an explosion.
When opening a battery compartment, always allow
ample time for battery gases to escape.
• If the battery is corroded, clean it with a mixture of
warm water and baking soda.
• If battery acid gets on the skin or in the eyes, flush
the area immediately with fresh water and seek
medical attention.
Check the battery’s condition only with proper test
equipment.
Disconnect the Battery
When disconnecting the battery, always disconnect the
negative (-) cable first, then disconnect the positive (+)
cable.
NOTE:
Disconnecting the jumper cable between the
batteries may not completely interrupt the
electrical system.
Содержание SY95C
Страница 2: ...Page Intentionally Blank ...
Страница 146: ...5 48 MAINTENANCE SY95C Excavator OMM Page Intentionally Blank ...
Страница 151: ...SPECIFICATIONS 6 5 SY95C Excavator OMM Load Point Radius and Height 0003873 Figure 6 3 ...
Страница 154: ...6 8 SPECIFICATIONS SY95C Excavator OMM Page Intentionally Blank ...
Страница 164: ...I 6 SY95C Excavator OMM ...
Страница 165: ...Page Intentionally Blank ...