― 58 ―
― 57 ―
6-3 Battery and Fuse Replacement
1. Do not open the rear case with live measuring terminals to avoid
electric shock. Also, make sure the meter power is OFF, before
starting replacement.
2. Be sure to use the specified fuse. Neither use unspecified fuse nor
short-circuit the fuse holder.
WARNING
Pre-installed battery
Since the pre-installed battery is for monitoring, it may not be
durable as typically expected.
*The purpose of the battery for monitoring is to check for the
functions and performances of the product.
Replacement procedure
①
Remove the holster and loosen the Philips-head screw fixing
the battery door using appropriate screw driver.
②
Remove the battery door and replace the battery or fuse with
new one.
Caution: Pay attention to the polarity when replacing the battery.
③
Re-fasten the screw and set the holster again.
6-4 Storage
Save the instrument into an appropriate place, according to the
precautions above.
1. The panel and case are not resistant to volatile solvents. Do not wipe
out with solvents or isopropyl alcohol. Clean the instrument up with a
dry soft cloth.
2. The panel and case are not resistant to heat. Keep it away from heat-
generating devices such as solder irons.
3. Do not save the instrument into vibratory places or where the
instrument may fall off.
4. Do not expose the instrument to direct sunlight and do not save it
into any places with extreme temperature, humid, or condensation.
5. Remove the battery for saving the instrument over a long period of
time.
CAUTION
Battery door
Screw
for the battery door
Battery
Fuse
0.4 A/1000 V
φ
6.3×32 mm
Breaking capacity:30 kA
Part number
:
F1211
Rear case
Fuse
11 A/1000 V
φ
10×38 mm
Breaking capacity:20 kA
Part number:F1412
Содержание PC7000
Страница 1: ...PC7000 DIGITAL MULTIMETER 取扱説明書 INSTRUCTION MANUAL ...
Страница 17: ... 30 29 備 考 m m m m D 時にはバーグ ラフは表示されません m m m m D ...
Страница 25: ... 46 45 備考 4 20 mA 測定では DC 4 mA を 0 とし DC 20 mA を 100 とした場合のパーセンテージ を表示します m 4 20 mA m m m m m Hz ...
Страница 40: ...PC7000 DIGITAL MULTIMETER INSTRUCTION MANUAL ...
Страница 56: ... 30 29 Note The display style of m m m m or D does not show the bar graph m m m m D ...