SANUVOX - MODEL S300FX-GX
- 11
3. GENERAL OPERATING INFORMATION
DOOR SWITCH
MODE SELECTOR
OPERATIONS
SMART SYSTEM
LED STATUS DISPLAY
FUNCTION
The HEPA/UV air purifier is comprised of a
ventilator, speed selection switch, 2 stages of
filtration and the cabinet enclosure system.
The ventilator pulls air through the prefilter
and pushes the same air through the HEPA
filter which removes 99.97% of particles that
are 0.3μm or larger in size.
The S300FX-GX HEPA/UV Purifier is designed
to kill bacteria, viruses, odor causing mold and
fungus as well as chemical odors and VOC's
that pass through the unit. The ultra-violet band
light inhibits and kills mold, fungus, bacteria,
viruses and microbial growth on 100% of
the air flowing through the unit. The actual
percentage of destruction depends on the
velocity of the air, and the pollutant(s) treated.
LED DISPLAY
The UV Lamp will function when the blower is
in operation. There are two LED indicators on
the front panel. The Amber LED indicates that
the UV Lamp is on; the Red LED indicates that
the Ballast is functioning. If the Ballast (Red)
LED is on, and the Lamp (Amber) LED is off,
the UV lamp is not functioning. If both LED
lights are off, the ballast is not functioning.
RECOMMENDED OPERATION
The return plenum mount model operates in
conjunction with your forced air HVAC system.
A forced air distribution system continuously
circulates the air inside your home. The HEPA/
UV air purifier operates on the principal of
bypass filtration, which means that a portion of
the air being returned to the furnace is filtered
on each pass. Over time all the air in the home
will pass through the unit. It is recommended
that the furnace blower be in operation
whenever the system is in operation.
For stand-alone attic installation, the HEPA/
UV air purifier must be operated continuously
whenever a part of the system is located in an
unconditioned space to avoid condensation in
the ductwork when the temperature is below
freezing (32°F ,0°C).
Maintenance of the unit should be performed
at regular intervals to keep the benefits of the
HEPA/UV air purifier.
OPERATION MODE OPTIONS
The unit features two speeds of operation. The
speed selection switch is located on the front of
the motor assembly. At lowest speed the unit will
provide 220 CFM of clean air while at highest
speed, the unit will provide 300 CFM of clean air.
It is recommended that the unit be operated on
the highest speed at all times to maximize the
benefits of the HEPA/UV air purifier.
An access door is provided at the front of the
unit to permit access to the filters and speed
selection switch. Opening the latch on the right
side of the unit will permit the door to swing
open. A safety door interlock switch cuts the
power to the motor. If necessary, the door can
be removed from the cabinet hinges by holding
the top part of the door with one hand and gently
taping on the bottom edge of the door with the
other hand to release the door from its hinges.
OWNER’S OPERATION GUIDE
• II
• I
Maximum Filtration
Normal Filtration
S300FXSP - 120V Manual Eng.indd 11
2015-03-18 16:33