- 5
INSTALLATION GUIDE
SPECIAL CONSIDERATION
FOR INTEGRATED SYSTEM INSTALLATION
• Verify clearance on the ductwork to mount
the unit using the Forced Air Heating/
Cooling system
• Respect the Minimum clearance
requirements for maintenance and service
• Electrical power requirements
• Interaction between the HEPA/UV air purifier
unit and other mechanical devices.
DUCTING FLAIR SYSTEM INSTALLATION
The HEPA/UV air purifier system is designed to
install directly onto the return air plenum of the
HVAC system. This installation eliminates the
need to externally duct the HEPA/UV air purifier
to the plenum system. With this installation, it
is recommended that you run the fan on your
forced air system continuously to maximize its
cleaning ability.
TIPS TO INSTALLER
The HEPA/UV air purifier does not replace
the filter from the HVAC system. Regular
maintenance of this filter is necessary for
proper performance of the system.
OPTIONAL MOUNTING COLLAR SYSTEM
INSTALLATION
Using Part Number: Collars1, the HEPA/UV air
purifier can be converted to use 8 inch round
collars for applications that require ducting.
The kit includes two, 8 inch round collars, two
mounting brackets for wall or floor mounting,
installation guide and fasteners.
DUCTING FLAIR SYSTEM
(MOUNTED ON DUCT)
The HEPA/UV air purifier is a versatile appliance with multiple installations configuration. It is
recommended to take your time in planning the installation.
A number of installations follow for HEPA/UV air purifier applications:
• Return duct to Return duct integrated with the forced air HVAC system.
• Central draw points using a dedicated duct system.
• Consult Sanuvox for other special applications.
2.1 PLANNING THE INSTALLATION
2.2 TYPE OF INSTALLATION: RETURN TO RETURN
INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL.
Consult your HVAC product manufacturer if the usage of this product will affect the performance of
your forced air heating/cooling system.
Return
Air Plenum
Return
Air Plenum
To living
space
To living
space
Forced Air Heating/Cooling System
Forced Air Heating/Cooling System
OPTIONAL COLLAR SYSTEM
(MOUNTED ON WALL)