Item
Standard or Performance
Notes
A11H202U***TW A11H302U***TW
UL MODEL
011 111 011 111
A11H202A***USTW(P)* A11H302A***USTW(P)*
Type
011 111 011 111
Output capacity
2kVA/1.4 kW
3kVA/2.1kW
Cooling system
Forced air cooling
Input power plug
NEME 5-20P
NEMA L5-30P
Phases
Single phase, 2-wire
Voltage
55 to 150V
Rated Voltage
:
120V (*6)
Frequency
40 Hz to 120 Hz
±
1, 3, 5%: Sync Range
Power requirements
1.8 kVA
2.7kVA
Max. capacity during battery charging
AC in
put
Input power factor
0.95 or more
During rated output (*2)
Outlet
NEMA 5-20R
×
4 NEMA
L5-30R
×
1
Phases
Single phase, 2-wire
Voltage 120
V
Voltage regulation
Rated voltage
±
2%
Rated frequency
50 Hz or 60 Hz
User settable
Frequency regulation
Rated frequency within
±
1, 3 or 5%:
1, 3, 5% selectable
Free running
±
0.5%
Voltage waveform
Sine wave
Distortion factor of
voltage waveform
Linear load: 3% or less
100% rectifier load: 7% or less
During rated output
Rapid load
change
0%
⇔
100% at transient or output switch
Power outage,
recovery
Rated voltage
±
5%
During rated output
Transient
voltage
variation
Rapid input
voltage change
±
10% variation
Response time
5 cycles or less
Load power factor (lag)
0.7 (lag)
Variation range 0.7 (lag) to 1.0
Overcurrent protection
Auto switch to bypass circuit at 105% or more
Inverter 105%
200
ms
200% 30
seconds
AC Outp
ut
Overload
capability
Bypass
800% 2
cycles
Type
Small sealed lead battery
Number
8
12
10
15
12V per battery
Rated capacity
136W
2 parallel
136W
3 parallel
170W
2 parallel
170W
3 parallel
15 minute-rate
Batteries
Backup time
12 minutes 20 minutes 10 minutes 18 minutes
At 25°C (77°F) ambient temperature,
rated load, with new battery
Generated heat
250W
370W
Input leakage current
3 mA or less
Operating environment
Ambient temperature: 0 to 40°C (32 to 104°F)
Relative humidity: 20 to 90%
(*3)
Acoustic noise
45dB or less
50dB or less
1 m (approx. 40 inches) from UPS front
panel, 'A' characteristics (linear load)
Safety standard
UL1778-4th/C22.2 No.107.3-05-2nd:2005
Emission
FCC Part15 Sub partB Class-A
(*1): The inverter is capable of operation synchronized with AC input frequency and instantaneous
switchover provided that the AC input frequency is within the rated frequency, and the AC input
voltage is within the rated voltage.
(*2): When input voltage waveform distortion is under 1%.
(*3): The UPS contains batteries. Battery service life will be foreshortened if the UPS is used in an
environment where the ambient temperature exceeds 30°C (86°F).
(*4): If grounded, the ground phase of the input and output must match according to UPS specifications.
(*5): The above table lists standard specifications. Some specifications are different for units with long
backup times. For details, refer to the external battery specification instruction manual.
(*6): When AC input voltage is within 55V to 96V, the load capacity is derated from the rated capacity of
the UPS.