The 2 grindstones are identical and can be fitted equally either on the moving plate (18)
(moving grindstone) or on the adjusting "nut" (5) (fixed grindstone) (fig. F).
1. Close the bean shutter (6) (fig. G) .
2. Run the machine until the coffee beans waiting in the grinder body have gone
through.
3. Stop the machine and unplug the mains power lead (10).
4. Take off the bean container (2).
5. With one hand, press on the
indexing pointer (7)
and with the other unscrew the
adjustment nut by turning it in an anti-clockwise direction (fig. H).
CARE
:
When this part is fully unscrewed, handle it with care so as not to damage
the brass thread.
6. Unscrew the 3 screws on each grindstone (fig. I). For the moving grindstone, place a
screwdriver across the grinder body and the coffee outlet conduit to stop the
grindstone-carrier plate from turning on unscrewing or screwing up the grindstone
retaining screws.
7. Carefully clean the whole grinder body, in particular the grindstone facing areas.
8. Place each grindstone on its support making sure that there is no coffee dust
between the grindstone and its support.
CARE
:
The slightest small coffee particle under the grindstone may prevent the
machine from operating correctly. It is recommended that the grinder body is cleaned
with a compressed air jet or a dry brush.
CARE
:
do not unscrew the grindstone-carrier plate (18) retaining spindle (17) so as
not to upset the assembly geometry
(fig. J)
.
9. Once the 2 grindstones have been replaced, with one hand press the indexing
pointer (7) and with the other place the "ground coffee adjustment nut" (5) on the
grinder body taking care not to damage the thread. Without using force, put the "nut"
(5) on the grinder body unscrewing it gently to feel for alignment of the two threads
and thus to be able to feed them in without using force. Then tighten until the 2
grindstones come into contact (fig. K).
10. Unscrew the "adjustment nut" (5) to free the grindstones in contact.
11. Plug the machine in and switch it on with no coffee.
12. While pressing the indexing pointer with one hand, with the other screw up the
"adjustment nut" (5) until the 2 grindstones make
slight
contact.
13. Stop the machine.
14. Unscrew the graduated plate (12) retaining screws and re-index the graduated plate
"0" with the indexing pointer (7) (fig. L).
15. Unscrew the "adjustment nut" (5) by 5 to 10 notches
16. With coffee, adjust the ground coffee setting (see "Coffee grinding adjustment"
section).