The evaporator operates in a flooded condition, which means
that all the evaporator tubes contain liquid refrigerant during
normal operation. A flooded evaporator should maintain
constant pressure and temperature across the entire coil,
from inlet to outlet. The mixture of gas and liquid refrigerant
enter the accumulator after leaving the evaporator coil. The
accumulator prevents any liquid refrigerant from reaching the
compressor. The compressor evacuates the cool refrigerant
gas from the accumulator and compresses it to a high
pressure and temperature gas to repeat the process.
8.2 Troubleshooting
FOR THE HOMEOWNER:
n
If the unit does not work properly, please check the
following:
— Is the unit unplugged?
— Is power to outlet on? (check switch, if applicable)
— Is circuit breaker tripped?
— Is humidity control set? (turn to “ON”)
— Is air flow restricted? (check air filters and grill)
If none of the above, call dealer or 1-800-533-7533, Ext.
8459.
FOR THE HVAC PROFESSIONAL:
n
No dehumidification. Neither blower, nor compressor run
with fan switch AUTO.
1. Unit unplugged or no power to outlet, circuit breaker
tripped.
2. Humidity control set to “Humid” setting.
3. Loose connection in internal wiring.
4. Humidity control is defective.
n
No dehumidification. Compressor does not run but
blower runs with fan switch AUTO and humidity control
turned to ON.
1. Defrost thermostat open, ambient temperature too low.
2. Loose connection in compressor circuit.
3. Defective compressor overload.
4. Defective compressor or compressor run capacitor.
n
Blower runs with fan switch AUTO but compressor
cycles on & off.
1. Low ambient temperature and/or humidity causing unit
to cycle through defrost mode.
2. Defrost thermostat defective.
3. Defective compressor overload.
4. Defective compressor.
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
6
Santa Fe Advance2 Installer’s & Owner’s Manual
n
Blower does not run with fan switch in either position.
Compressor runs briefly but cycles on and off.
1. Loose connection in blower circuit.
2. Obstruction prevents impeller rotation.
3. Defective blower.
4. Defective blower switch.
n
Evaporator coil frosted continuously, low
dehumidifying capacity.
1. Dirty air filter or air flow restricted.
2. Defrost thermostat loose or defective.
3. Low refrigerant charge.
If none of the above has fixed the issue, call
technical support at 1-800-533-7533, Ext. 8459.
9. Service Parts List -
Call your dealer or 1-800-533-7533.
Part No
Description
4034011-02 Evaporator
4032702
Capillary Tubes
4028089
Compressor
1970010
Compressor Relay
4029510 Filter/drier
4034109 Condensor
4032196 Impeller
4033032-03
35mfd 370V Capacitor - Compressor
4033031-02
5mfd 370V Capacitor - Impeller
4026221
Leveling Foot
4031376
Defrost Thermostat
4027172
Humidity Controller
4025560
Fan Switch
10. Accessory/Replacement Parts -
Call your dealer or order online.
4031062
MERV 8 Filter (1.75"x14"x17.5")
4033036
MERV 8 Filters 4-Pack
4033037
MERV 8 Filters 12-Pack
4035319
MERV 11 Filter (1.75"x14"x17.5")
4035131
MERV 11 Filters 4-Pack
4035132
MERV 11 Filters 12-Pack
4033038
Pump Kit
4028616
Caster Kit
4026450
Leveling Foot Kit
4033039
Duct Kit, Supply Only
4026969
10" Flex Duct
4022126
10" Flex Insulated Duct
4020175
Remote Dehumidistat