Santa Fe 4032230 Скачать руководство пользователя страница 3

3

1-800-533-7533 | www.Santa-Fe-Products.com

Santa Fe Impact Installation & Operation Instructions

Safety Instructions

•  Never operate a unit with a damaged power cord. If the power cord is damaged, it must be replaced by the manufacturer, 

its service agent, or a similarly qualified person in order to avoid a hazard.

•  Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or power receptacle.
•  When plugging in the unit, use a Ground Fault Interrupter outlet.
•  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, 

or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the 

appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the 
appliance.

•  Never operate electrical equipment near or in standing water.
•  Do not stick your fingers or other objects through the safety grill.
• The unit must be used in the upright position.
•  When changing filters, do not stick fingers or other objects in the unit.
•  Do not restrict airflow in to or out of the unit. This may cause the unit to overheat.
•  The unit should never be serviced or cleaned while it is plugged in.
• Do not sit or stand on the unit, or use as a shelf or table.
•  Before leaving the unit unattended, ensure children do not have access to the equipment. Do not allow children to play with 

or near the unit or in its air flow.

•  The unit is designed to be installed indoors only.
•  No user serviceable components. Contact installer or call 1-800-533-7533 for all repair or warranty needs.

Intended Application(s)

The Santa Fe Impact is intended for use in crawlspaces or basements: however, the unit can be placed in almost any 
residential setting where dehumidification is desired. Use in non-residential applications and pool areas may void warranty.
The Santa Fe Impact is designed to operate in temperatures between 56° and 95°F. 
In order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of water 
intrusion or excessive fresh (outside) air infiltration. Before installing the Santa Fe Impact, water intrusion and air infiltration 
problems should be addressed.

Registrations

The Santa Fe Impact conforms to unified standard UL 60335-2-40 and CSA standard C22.2.60335-2-40.

READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING AND OPERATING THIS DEVICE. PROPER ADHERENCE TO THESE  
INSTRUCTIONS IS ESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE  
DEHUMIDIFIER.

 

WARNING!

THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN 
SERIOUS INJURY OR DEATH.

 

CAUTION!

THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN 
INJURY OR MATERIAL PROPERTY DAMAGE.

Содержание 4032230

Страница 1: ...ies up to 2 500 square feet and is the ideal unit for meeting aggressive energy use targets The Santa Fe Impact is engineered for extremely quiet operation and is optimized for low heat load P N 40322...

Страница 2: ...Precautions 5 Location Considerations 5 Installing Leveling Feet 5 Ducting to Finished Areas Optional 6 Attaching Duct Collars 6 Recommended Installations 7 Drain Installation 8 Operation 9 Humidity C...

Страница 3: ...shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be...

Страница 4: ...nts Day 85 Pints Day Efficiency 8 8 Pints kWh 7 8 Pints kWh Energy Factor 4 2 L kWh 3 7 L kWh Air Filter MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 9 115 VAC Ground Drain Connection 3 4 Thread...

Страница 5: ...a 15 Amp circuit capacity The unit is designed to operate while level If the unit is placed on an unlevel surface refer to section below Installing Leveling Feet Failure to level the unit may result i...

Страница 6: ...r duct collar and a front panel are attached to the unit Supply Air Outlet Two 10 diameter duct collars attach to the outlets on each side of the unit CAUTION BOTH EXHAUST OUTLETS MUST BE LEFT OPEN OR...

Страница 7: ...m being placed under a negative pressure and also allow the dehumidifier to focus on keeping the unfinished area dry as well The onboard dehumidistat control can be used on the unit for this applicati...

Страница 8: ...Optional Drain Port Drain Trap Pretzel Loop Floor Bend PVC Trap PVC materials available from your local hardware store Standard Loop The Santa Fe Impact requires a drain trap Creating a drain trap all...

Страница 9: ...he humidity dial clockwise to the recommended NORMAL position and set fan control to FAN AUTO To turn the unit off turn the humidity dial counter clockwise to the OFF position and set fan control to F...

Страница 10: ...SE PREMATURE FILTER WEAR OR UNIT DAMAGE MERV 8 Filter Changing the Filter For greatest filtration and efficiency of the Santa Fe Impact it is recommended the air filter be replaced every three to six...

Страница 11: ...11 1 800 533 7533 www Santa Fe Products com Santa Fe Impact Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Страница 12: ...Amp circuit capacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any furthe...

Страница 13: ...TA FE IMPACT WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE ONLY QUALIFIED SERVI...

Страница 14: ...s temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will...

Страница 15: ...oes not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer C...

Страница 16: ...www Santa Fe Products com 1 800 533 7533...