Santa Fe Impact Installation & Operation Instructions
Service
Replacement Parts
4026221
Leveling Foot
4031085
Condensor Coil
4031086-05 Evaporator Coil
4025741
Thermostat, Defrost Control
4029510 Filter/Drier
4035851 Compressor
4035871
Compressor Overload
4032196 Impeller
4025560
Fan Switch
4035087 Humidistat
4035235-02 Blower Capacitor, Run, 5MFD, 370V
4033032-03 Compressor Capacitor, Run, 35MFD, 370V
Refrigerant Charging
If the refrigerant charge is lost due to service or a leak,
a new charge must be accurately weighed in. If any of
the old charge is left in the system, it must be recovered
before weighing in the new charge. Refer to the
unit nameplate for the correct charge weight and
refrigerant type.
Compressor/Capacitor Replacement
This compressor is equipped with a two terminal
external overload and a run capacitor, but no start
capacitor or relay.
WARNING!
SERVICING THE SANTA FE IMPACT, WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE
CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR
PROPERTY DAMAGE. ONLY QUALIFIED SERVICE PEOPLE SHOULD SERVICE THIS UNIT.
Troubleshooting
CAUTION!
TROUBLESHOOTING SHOULD BE PERFORMED BY
A QUALIFIED HVAC TECHNICIAN.
Symptom
Possible Reason
Neither fan nor
compressor
running.
Dehumidification
is being called for.
Compressor is
not running.
Dehumidification
is being called for.
Fan is running.
1. Defective compressor
run capacitor.
2. Loose connection in
compressor circuit.
3. Defective compressor
overload.
4. Defective compressor.
5. Defrost thermostat open.
Compressor
cycles on and off.
Dehumidification is
being called for.
1. Low ambient
temperature and/or
humidity causing unit
to cycle through
defrost mode.
2. Defective compressor
overload.
3. Defective compressor.
4. Defrost thermostat
defective.
5. Dirty air filter(s) or air
flow restricted.
6. Defective fan or relay.
1. Dehumidifier unplugged
or no power to outlet.
2. Humidity control set
too high.
3. Loose connection in
internal or control wiring.
4. Defective compressor
relay.