background image

11

1-800-533-7533 | www.Santa-Fe-Products.com

Santa Fe Impact Installation & Operation Instructions

MERV Rating Chart

Air Filtration

http://www.mechreps.com/PDF/Merv_Rating_Chart.pdf

Содержание 4032230

Страница 1: ...ies up to 2 500 square feet and is the ideal unit for meeting aggressive energy use targets The Santa Fe Impact is engineered for extremely quiet operation and is optimized for low heat load P N 40322...

Страница 2: ...Precautions 5 Location Considerations 5 Installing Leveling Feet 5 Ducting to Finished Areas Optional 6 Attaching Duct Collars 6 Recommended Installations 7 Drain Installation 8 Operation 9 Humidity C...

Страница 3: ...shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be...

Страница 4: ...nts Day 85 Pints Day Efficiency 8 8 Pints kWh 7 8 Pints kWh Energy Factor 4 2 L kWh 3 7 L kWh Air Filter MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 9 115 VAC Ground Drain Connection 3 4 Thread...

Страница 5: ...a 15 Amp circuit capacity The unit is designed to operate while level If the unit is placed on an unlevel surface refer to section below Installing Leveling Feet Failure to level the unit may result i...

Страница 6: ...r duct collar and a front panel are attached to the unit Supply Air Outlet Two 10 diameter duct collars attach to the outlets on each side of the unit CAUTION BOTH EXHAUST OUTLETS MUST BE LEFT OPEN OR...

Страница 7: ...m being placed under a negative pressure and also allow the dehumidifier to focus on keeping the unfinished area dry as well The onboard dehumidistat control can be used on the unit for this applicati...

Страница 8: ...Optional Drain Port Drain Trap Pretzel Loop Floor Bend PVC Trap PVC materials available from your local hardware store Standard Loop The Santa Fe Impact requires a drain trap Creating a drain trap all...

Страница 9: ...he humidity dial clockwise to the recommended NORMAL position and set fan control to FAN AUTO To turn the unit off turn the humidity dial counter clockwise to the OFF position and set fan control to F...

Страница 10: ...SE PREMATURE FILTER WEAR OR UNIT DAMAGE MERV 8 Filter Changing the Filter For greatest filtration and efficiency of the Santa Fe Impact it is recommended the air filter be replaced every three to six...

Страница 11: ...11 1 800 533 7533 www Santa Fe Products com Santa Fe Impact Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Страница 12: ...Amp circuit capacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any furthe...

Страница 13: ...TA FE IMPACT WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE ONLY QUALIFIED SERVI...

Страница 14: ...s temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will...

Страница 15: ...oes not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer C...

Страница 16: ...www Santa Fe Products com 1 800 533 7533...