4.06 Parameter Selection
The Table below provides information of the parameters that are available for modification using the
front panel display. The table also provides information on the ranges available for each parameter
as well as to which weld process the parameter is available.
TABLE 4-3 : Front Panel Parameter Selection Ranges.
*1 : The values listed in the “Default” column are the “Factory Default Settings”. Once these are
changed, the last setting(s) before the unit is turned off will remain in memory for the next turn
on. These NEW settings will become the new default setting. The user must manually adjust
the setting to the values in the above chart to return to the “Factory Default Settings”.
*2 : Pulse frequency units are dependent on frequency setting range as shown below:
TABLE 4-4 : Front Panel Parameter Selection Ranges.
*3 :
The minimum value in AC mode and AC-SOFT mode is 10A.
The maximum value in AC-SOFT mode is 200A.
*4 :
The VR current cannot be set beyond the output current range.
The minimum output current is 10 A.
The maximum output current is 300A in AC mode and 200A in AC-SOFT mode.
Process
PARAMETER
RANGE
Default *1 Units
STK LFT HF
AC Frequency
15 to 150Hz
60Hz
1Hz
YES YES YES
Wave Balance
10 to 65%
20%
1%
YES YES YES
VR Current
-99 to 100A *4
0A
1A
YES YES YES
Weld Current
5 to 300A
*3
120A
1A
YES YES YES
Pulse Base Current
5 to 300A *3
80A
1A
NO YES YES
Pulse Peak Current
5 to 300A *3
120A
1A
NO YES YES
Hot Current
0 to 70A
20A
1A
YES NO YES
Initial Current
5 to 300A *3
30A
1A
NO YES YES
Crater Current
5 to 300A *3
30A
1A
NO YES YES
Pulse Duty
15 to 80 %
50%
1%
NO YES YES
Pulse Frequency
0.5 to 500.0 Hz
100.0Hz
*2
NO YES YES
Pre-Flow Time
0.0 to 25.0 sec
0.1sec
0.1sec
NO YES
YES
Post-Flow time
0.0 to 60.0 sec
10.0sec
0.1sec
NO YES
YES
Spot Time
0.1 to 25.0 sec
2.0sec
0.1sec
NO NO
YES
Up-Slope Time
0.0 to 25.0 sec
1.0sec
0.1sec
NO YES
YES
Down-Slope Time
0.0 to 25.0 sec
3.0sec
0.1sec
NO YES
YES
Setting range
Units
0.5 to 20 Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz
Содержание IA-3000TP-U3E
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 26: ...26 PAGE LEFT INTENTIONALLY BLANK ...
Страница 32: ...32 PAGE LEFT INTENTIONALLY BLANK ...
Страница 54: ...54 PAGE LEFT INTENTIONALLY BLANK ...
Страница 74: ...74 PAGE LEFT INTENTIONALLY BLANK ...
Страница 87: ...87 PAGE LEFT INTENTIONALLY BLANK ...
Страница 94: ...PAGE LEFT INTENTIONALLY BLANK ...
Страница 97: ...PAGE LEFT INTENTIONALLY BLANK ...