49
PARAMETER
DESCRIPTION
AC-SOFT mode.
DOWN SLOPE
This parameter operates in TIG modes only and is used to set the time for
the weld current to ramp down, after the torch trigger switch has been
pressed, to
CRATER CUR.
This control is used to eliminate the crater that
can form at the completion of a weld.
CRATER CUR.
This parameter operates in
SLOPE
or
REPEAT
(4T) TIG modes only and
is used to set the finish current for TIG. The CRATER Current remains on
until the torch trigger switch is released after it has been depressed.
POST-FLOW
This parameter operates in TIG modes only and is used to adjust the post
gas flow time once the arc has extinguished. This control is used to
dramatically reduce oxidation of the tungsten electrode.
SAVE/LOAD
The SAVE/LOAD buttons are used to save and retrieve a total number of 30
programs into the 300AP memory.
SAVE the Current Weld Parameters into Memory
•
Press the
SAVE
button
•
Select a memory location by rotating the control knob, 1 to 30 is displayed
on the meter.
•
After selecting the desired memory location (ie 1 to 30), press the right
scroll button and the machine will give a beep to confirm the weld
parameters from the control panel are saved.
LOAD (retrieve) a Program to Control Panel
•
Press the
LOAD
button.
•
Select a memory location by rotating the control knob, 1 to 30 is displayed
on the meter.
After selecting the desired memory location (ie 1 to 30), press the right
scroll button and the machine will give a beep to confirm the weld
parameters are loaded onto the control panel.
When welding after the welding parameters have been changed, the revious
5 sets of welding parameter settings can be loaded.
Press the LOAD button and turn the Control Knob to select the history
number (“L. -1” to “L. -5”) you want to call up on the parameter display.
Example: Select -2 to recall the previous welding conditions.
Press the SET button to load the welding conditions that correspond to the
displayed history number.
STICK mode of operation.
HF TIG mode of operation. A remote control device may be used for use
during LIFT TIG operation. See section 4 for the 14-Pin Remote Control
Receptacle for complete details of the remote device.
Содержание IA-3000TP-U3E
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 26: ...26 PAGE LEFT INTENTIONALLY BLANK ...
Страница 32: ...32 PAGE LEFT INTENTIONALLY BLANK ...
Страница 54: ...54 PAGE LEFT INTENTIONALLY BLANK ...
Страница 74: ...74 PAGE LEFT INTENTIONALLY BLANK ...
Страница 87: ...87 PAGE LEFT INTENTIONALLY BLANK ...
Страница 94: ...PAGE LEFT INTENTIONALLY BLANK ...
Страница 97: ...PAGE LEFT INTENTIONALLY BLANK ...