86
Item
Specifications
Control signal
(1) Current signal: 4 to 20 mA (DC) (internal resistance: 250 Ω)
(2) Voltage signal: 1 to 5 VDC, 0 to 5 VDC (internal resistance:
10 kΩ)
Start/stop method
Soft start/stop method, 0.5 seconds (default value)
(Adjustable between 0.0 and 300 seconds)
Cooling method
Self cooling (for units with 75 A or less), air cooling (for units
with 100 A or more)
Input and output
characteristics
Linearity: ±3% FS (at 10% to 90% output)
(For the continuous cycle control method, linearity: ±5% FS)
(Characteristics of roots of 1.6, 1.8, 2.0, 2.2, 2.5, and 3.0 power
and average characteristics are available with the function
characteristic function.)
Current limitation
characteristics
Settable between 10% and 110% of the rated current (only for
phase control)
Warning output function
Two contact output systems. The output destination can be
switched.
Contact: normally open (250 VAC, 1 A/30 VDC, 1 A)
Withstand voltage
UG1-2***, UG1-2***F: 2000 VAC/1 min between the main
circuit and ground
UG1-4***F: 2500 VAC/1 min between the main circuit and
ground
Insulation resistance
20 MΩ or higher (500 VDC)