![SanRex CALPOTE UG Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/sanrex/calpote-ug-series/calpote-ug-series_instruction-manual_4646675020.webp)
20
(3)
Automatic adjustment 1 (4 to 20 mA [DC])
Set [F101: Temperature controller type] to [0: 4 to 20 mA (1 to 5 VDC)].
(1) Standard
(2) With the gradient setting
(3) With the lower point setting
(4) With the gradient setting
and the lower point setting
Gradient
Lower
point
Lower
point
Gradient
Temperature
controller
Temperature
controller
Temperature
controller
Temperature
controller