42
Code
Function name
Setting range
Increment
Unit
Default
value
Changeable
during
operation
F2_E
Priority of the
soft-start time
(E)
1
✗
F2_C
Priority of the
current limit
amount (C)
1
✗
F2_U
Priority of the
heater
disconnection
amount (U)
1: Panel
–
–
1
✗
F2_d
Priority of the
delay time (d)
2: Communication
1
✗
F2_t
Priority of the
interval (t)
1
✗
F2_n
Priority of the
function
characteristics
(n)
1
✗
The parameter values that can be checked and changed in PARAMETER mode can be set
using multiple methods. You can select the method to use for each parameter.
[0: Control terminal block input] selected
The signal applied to the control terminal block is used as the setting. The value entered on
the setting screen in PARAMETER mode is ignored. Requests to rewrite the setting sent via
communication are also ignored.
[1: Panel] selected
The value entered on the setting screen in PARAMETER mode is used as the setting. The
signal applied to the control terminal block is ignored. Requests to rewrite the setting sent via
communication are also ignored.
[2: Communication] selected
The value entered on the setting screen in PARAMETER mode is used as the setting and
can be rewritten via communication. The signal applied to the control terminal block is
ignored.
Содержание CALPOTE UG Series
Страница 60: ...60 9 2 External View Models with a rated current of 25 35 or 50 A Models with a rated current of 75 A...
Страница 61: ...61 Models with a rated current of 100 A Models with a rated current of 150 A Intake air Intake air...
Страница 62: ...62 Models with a rated current of 250 A Models with a rated current of 350 or 450 A Intake air Intake air...
Страница 94: ...94 APPENDIX B PANEL TRANSITION DIAGRAM...
Страница 96: ...MEMO...