Z1
No electrical devices
Z2
Electrical devices IPX4
Class2 (Standard
EN60335-2-43:2003/
A2:2008). Commands
not reachable from “Z1”
Z3
Class1 or Class2 electri-
cal devices with com-
mands not in “Z2”
2) How to connect
•
The device must be supplied with 230V, 50Hz;
• The installation must comply with local national regulations;
3) Maintenance
•
Switch off the device before any maintenance;
•
Twice a year dust off the device to keep it performing at its best. Do not use abrasive
products;
•
Do no install under a fixed socket and do not install shelves above the device; This
device should be installed so that the lowest heated rail is at least 600 mm above the
floor, in order to prevent injuries to very small children;
•
Keep a free space of 50 cm in front of the device;
• The thermostat should be at least 5mm far from the wall;
• This device is IP24 protection and in Class 2. It can be installed in zones 2 and 3 of
the bathroom;
14
USING THE DEVICE
Activation or
deactivation of
BOOST mode
BOOST mode
activation LED
• Setpoint temperature;
• Duration of the
BOOST;
Heating LED (lights
up when the heating
element is supplied)
On/Off switch
Manual
mode
Program
mode
Settings
Increase
Decrease
Lock (press the 2 keys)
• Change mode;
• Adjust the parameters;
• Validate;
•
Return (Long press);
CONTROLS AND FUNCTIONS