Sanosil Q-Jet C10  

Operating Manual 

Des M03 

 operating manual Q-Jet C10 

16/20 

 
 

10.

 

Door sealing and attaching the warning information 

 

After leaving the room and closing the door, seal door and all other room openings with 
adhesive tape. 

To prevent unauthorized entry into the room, a clearly visible notice 

must be attached to the doors or door handle, displaying the start and calculated end 
time of the disinfection process (incl. application time). 

 
During the aerosol process and the application time, do not enter the room, as aerosol 
fog will escape when the doors are opened and may cause irritation to the eyes or air-
ways in other rooms.  
 

 

 

 
 

WARNING

 

Risk of injuries!

 

This device nebulizes chemical substances!

 

Misted disinfectants are very light floating. Avoid that disinfection mist from leaks 
penetrates into other rooms not intended for treatment!

 

 

 

11.

 

Re-entering procedure and using the room  

 

After the end of the minimum application time (table on the right), the 
aerosol concentration normally falls to a harmless level; the hydrogen 
peroxide breaks down to form water and oxygen. This happens more 
quickly if organic material is present. If the dosage is too high or if there 
are smooth surfaces in the room which have been very well cleaned, the 
decomposition process may be slower, as the hydrogen peroxide cannot 
react properly with oxidizable substances (e.g. microorganisms). 

 

Right procedure:

 

 

 

Check with a hydrogen peroxide level sensor that the H

2

O

2

-Level is 

below your local maximum permissible value or if not specified at 
least below 1 ppm. Use full protection equipment if unsure of the H

2

O

2

-Level in the room. 

 

 

If H

2

O

2

 level is too high, either detected with a level sensor or a strong hydrogen peroxide smell is no-

ticed, open windows and doors for minimum 15 minutes, unseal HVAC vents and restart HVAC system 
to allow increased airflow circulation in the room. 

 

 

Remove all previously attached tape sealings, fire alarm covers and HVAC covers. 

 

 

 

Disinfected room is now ready for use again. 

 

 

 

 
 

WARNING!

 

Risk of injuries!

 

To prevent injuries do always check H

2

O

2

-Level before entering the room.

 

When entering room to measure the H

2

O

2

-Value, do always wear full protection equip-

ment,

 

i.e. protection mask, safety googles and gloves.

 

The disinfected room can only be entered without protection equipment if the H

2

O

2

-Value 

is below the local maximum 

permissible

 value specified by the authorities.

 

 
 

 

Nebulization 
time 

Minimum 

waiting time 

 20 min 

120 min 

20 

 30 min 

130 min 

30 

 40 min 

140 min 

40 

 50 min 

150 min 

50 

 60 min 

and above 

160 min 

 

 

Содержание Q-Jet C10

Страница 1: ...Des M03 operating manual Q Jet C10 1 20 Sanosil Q Jet C10 Operating Manual SANOSIL AG CH 8634 Hombrechtikon Schweiz E Mail info sanosil com Internet www sanosil com ...

Страница 2: ...Sanosil Q Jet C10 Operating Manual Des M03 operating manual Q Jet C10 2 20 ...

Страница 3: ...2 Manual spray and wipe disinfection 10 5 3 Closing and sealing openings 10 5 4 Covering the fire alarm 10 6 Positioning Room volume Determining the dosage 11 6 1 Positioning of the Q Jet 11 6 2 Measuring the room volume determining the dosage 11 6 3 Establish nebulization time 12 7 Introducing of the Control elements 13 8 Prepare the device for operation 14 8 1 Filling 14 8 2 Power Connection and...

Страница 4: ...ptimally suited for the 3D aerosol disinfection of small rooms and vehicles such as ambulances buses trams etc up to a volume of max 80 100 m3 It impresses with its favorable dimensions simple operation high reliability and low noise emission Description of the device AC power 220 240V 50 60 Hz Current 1A Fuse max 4A Power 170W Air flow 50 L min 3 m3 h Dimensions 265x220x200mm with handle and legs...

Страница 5: ...Frontside Backside 1 Carrying handle 8 Housing 2 Signal lamp 9 Flow rate selector switch 3 ON OFF switch 10 Fine mist nozzle 4 Control panel 11 Ventilation and compressor cooler openings 5 Power cord 12 Dosing table 6 Fluid connection coupling 13 Power cord holder 7 Fluid tank Sanosil Disinfectant ...

Страница 6: ...d industrial areas It is an additional measure following regular cleaning and disinfect ing room surfaces Pre cleaning protocol is defined by the respective healthcare facility WARNING Risk of Damage This device nebulizes chemicalsubstances The area to be disinfected may only contain items necessary for its use Objects made of delicate organic materials in particular antiques paintings and pre cio...

Страница 7: ...weight Before removing the rear panel always disconnect the device from the power supply When there is liquid inside the tank do not tilt the device it could leak from the hydraulic circuit Read carefully all indications stated on the label of the Sanosil disinfectant 3 5 Authorized Persons The device shall only be used by adults who have been carefully instructed on how to operate it and are well...

Страница 8: ...ard Do not plug in if electrical plug or parts are wet 8 Use only a Sanosil supplied electrical power cord 9 Take care to prevent water or other fluid from entering the device Should this occur allow to com pletely dry before use Check the accuracy of all operating functions 10 Always unplug the power cord from the outlet before moving the device 11 There are no user serviceable parts inside the d...

Страница 9: ...e time has elapsed before using the room unit again Advantages Time consumption 2 5 hours depends on the room size humidity and the decomposition time of hydrogen peroxide in the treated room Sanosil Q jet C10 and room can be re used faster Disadvantages Needs measuring of the H202 level for security reasons Additional personal and time needed for hydrogen peroxide level measurements C Standard di...

Страница 10: ...ly reduced or to stop it escaping from the room all connections to other rooms or the out side must be closed and sealed with tape if possible These include windows skylights hatches service ducts etc and all doors apart from the one needed to enter or leave the room after starting the unit If necessary openings for air conditioning and ventilation systems can be sealed using HVAC cover plates Ven...

Страница 11: ...zle towards smoke detectors and check with facility management to take appropriate measures to avoid any activation of the detector systems during nebulization process WARNING Risk of discolorisation Minimum distance between Q Jet C10 and closest object 2 m If the distance falls below the minimum distance the Sanosil Disinfectant mist may condense on the surface and cause dark discoloration over t...

Страница 12: ... close to the unit 2m 10ml min and 20ml min Formula Room s volume in m3 x desired concentration 10 or 20 ml fogging time in minutes Example Room size 20m3 Desired Concentration 12ml m3 selectet Flow rate 10 ml min 20 x 12 240ml 10 24 min spray time Dosage and timetable for 8ml m3 and 12ml m3 Room size Fogging time Standard 8ml m3 Room size Fogging time Higher Risk 12ml m3 m3 Time m s Time m s Appr...

Страница 13: ...serve this may lead to condensation on surfaces with a risk of discoloration or corrosion WARNING Risk of Damage With reduced wall distance only operate with low flow rate Failure to observe this can lead to discoloration on walls ceilings or equipment Frontside Control Panel 1 On Off power switch 2 UP button 3 Down button 4 Screen Shows min and sec 5 Reset button 6 Start Stop button Sanosil Q Jet...

Страница 14: ...lose the tank bottle by screwing on the connector Put the full tank back into the device and connect it to the intake manifold Attached when it clicks Wipe up any spills with a microfiber towel or rag CAUTION Risk of Injuries Always wear gloves and safety googles when filling the bottle Do not overfill bottle or spill around Sanosil Disinfectants 8 2 Power Connection and Switch on the device Befor...

Страница 15: ...n shows T2 Fogging time min sec Press Start Stop button the countdown starts the red light on top of the device flashes and whole room disinfection process starts Please leave room immediately and seal door according description on page 14 A running disinfection program can be stopped anytime by pressing the button reset During the course of the disinfection program the display shows the remaining...

Страница 16: ... or if there are smooth surfaces in the room which have been very well cleaned the decomposition process may be slower as the hydrogen peroxide cannot react properly with oxidizable substances e g microorganisms Right procedure Check with a hydrogen peroxide level sensor that the H2O2 Level is below your local maximum permissible value or if not specified at least below 1 ppm Use full protection e...

Страница 17: ...ation Cycle Device in general Visual control Checking operationality fluid loss sealings caps dents breakages of parts Before every use Nozzle cleaning Cleaning cleaning with enclosed pin Monthly System cleaning Rinse the system with demineralized water Use bottle filled with 200ml demineralized wa ter and turn on the machine for 2 minutes Every two month Decommissioning for a longer period Run a ...

Страница 18: ...on Switch off device and let it cool down for 30 Min Check the settings Device emits loud noises Possible internal damages Presence of foreign bodies in the cooling fan Switch off and unplug device call service technician Device does not spray liquid Bottle incorrect attached Possible internal damages Internal piping rupture or con nections leaking Clean nozzle with nozzle cleaning tool Check all ...

Страница 19: ...er the claimed defect is discovered This warranty is available to the original purchasers only and cannot be transferred or assigned and does not ap ply to any parts equipment or other products not manufactured by the Manufacturer Except for the limited warranties expressly set forth above The manufacturer specifically disclaims any and all other warranties to buyer including without limitation an...

Страница 20: ...onmental pollution and to improve the recycling of raw materials a directive was issued by the European Commission which states that all electrical and elec tronic appliances have to be taken back by the manufacturer in order to dispose them properly or to make them available for recycling Within the European Union the devices marked with the symbol below may there fore not be disposed of together...

Отзывы: