After leaving the room and closing the door, seal door and all other room openings with
adhesive tape.
To prevent unauthorized entry into the room, a clearly visible notice
must be attached to the doors or door handle, displaying the start and calculated end
time of the disinfection process (incl. application time).
During the aerosol process and the application time, do not enter the room, as aerosol
fog will escape when the doors are opened and may cause irritation to the eyes or air-
ways in other rooms.
WARNING
Risk of injuries!
This device nebulizes chemical substances!
Misted disinfectants are very light floating. Avoid that disinfection mist from leaks
penetrates into other rooms not intended for treatment!
11.
Re-entering procedure and using the room
After the end of the minimum application time (table on the right), the
aerosol concentration normally falls to a harmless level; the hydrogen
peroxide breaks down to form water and oxygen. This happens more
quickly if organic material is present. If the dosage is too high or if there
are smooth surfaces in the room which have been very well cleaned, the
decomposition process may be slower, as the hydrogen peroxide cannot
react properly with oxidizable substances (e.g. microorganisms).
Right procedure:
•
Check with a hydrogen peroxide level sensor that the H
2
O
2
-Level is
below your local maximum permissible value or if not specified at
least below 1 ppm. Use full protection equipment if unsure of the H
2
O
2
-Level in the room.
•
If H
2
O
2
level is too high, either detected with a level sensor or a strong hydrogen peroxide smell is no-
ticed, open windows and doors for minimum 15 minutes, unseal HVAC vents and restart HVAC system
to allow increased airflow circulation in the room.
•
Remove all previously attached tape sealings, fire alarm covers and HVAC covers.
•
•
Disinfected room is now ready for use again.
WARNING!
Risk of injuries!
To prevent injuries do always check H
2
O
2
-Level before entering the room.
When entering room to measure the H
2
O
2
-Value, do always wear full protection equip-
ment,
i.e. protection mask, safety googles and gloves.
The disinfected room can only be entered without protection equipment if the H
2
O
2
-Value
is below the local maximum
permissible
value specified by the authorities.
Nebulization
time
Minimum
waiting time
0
–
20 min
120 min
20
–
30 min
130 min
30
–
40 min
140 min
40
–
50 min
150 min
50
–
60 min
and above
160 min