Sanosil Q-Jet C10
Operating Manual
Des M03
–
operating manual Q-Jet C10
11/20
6. Positioning / Room volume / Determining the dosage
6.1. Positioning of the Q-Jet unit
•
Avoid direction of air flow towards entrance door and air conditioning units.
•
Position the device in a corner of the room
(minimum rear distance to wall 30 cm to enable intake of room air).
•
Place device on a stable, flat, dust-free, no slippery, horizontal surface which can appropriately support
its weight.
•
Minimum distance between Q-Jet C10 and closest object (wall, door etc.): 2 m
If the distance falls below the minimum distance, the Sanosil Disinfectant mist may condense on the
surface and cause dark discoloration over time.
•
Point nozzle towards center of the room.
•
Do not point nozzle towards smoke detectors and check with facility management to take appropriate
measures to avoid any activation of the detector systems during nebulization process.
WARNING
Risk of discolorisation!
Minimum distance between Q-Jet C10 and closest object: 2 m
If the distance falls below the minimum distance, the Sanosil Disinfectant mist may
condense on the surface and cause dark discoloration over time.
6.2. Measuring the room volume / determining the dosage
In order to properly fill the room with the correct dosage of disinfectant, the room must
first be accurately measured and the room volume determined. This is done using tried
and tested laser test devices with integrated area and volume calculation.
The laser is used to measure the length, width and height of the room, and to calculate
the room volume in m
3
. In rooms which are heavily occupied with furniture, beds, tools,
etc. the calculated volume can be reduced by 5-10% if required.