Run the machine where air can be supplied in a stable condition.
Use after-cooler or similar equipment to supply clean air at all times.
Operation Procedures
1. Provide Air
The standard air pressure of this machine
is set at 0.6Mpa. Please make sure with
the pressure gauge that the air pressure is
0.6Mpa.
Low air pressure can cause malfunction. If the pressure does not reach its standard level, set
the air pressure properly following the procedure below.
Check Point
Check compressor if the main air pressure does not reach 0.6MPa even after the above
adjustment.
■
How to adjust air pressure
1.
Pull the adjustment knob up
2.
T
urn the knob to adjust air pressure
Clockwise
→
Pressure will increase
Counterclockwise
→
Pressure will decrease
3. Pull the knob down
Follow the procedure for proper operation.
Improper operation can cause mechanical failure or injury to operators.
CAUTION
Pressure Gauge
(0.6Mpa)
Attention
Air Inlet
14