11
Starting and Stopping the Conveyor by External Signals
When starting and stopping the conveyor frequently in a short period (tact operation etc.), it is impossible
to start and stop the machine by turning on/off the power supply. (Brushless-motor variable-speed type
is different from speed controller’s, and th
e power supply will trip.) In this case be sure to start and stop
the machine by external signals. For start and stop circuit by external signals, make connection to external
control circuit terminals on rear of control unit.
NOTE: Do not start and stop the conveyor excessively frequently. It may cause machine failure or shorten
NOTE:
its service life.
NOTE: 1. Be sure to ground earth.
NOTE:
2. AC line filter should be set up by user.
For details, refer to “Brushless
-
motor instruction manual”, appendix.
fig. Rear of control unit
Power cable
ground terminal
Motor
ground cable
Motor ground terminal
Brushless-
motor
Motor sensor connector
(black)
I/O signal connector
Motor
ground terminal
Motor connector (white)
Power cable connector
single phase
100-120V
Operation with small-capacity switch
and relay
Use a small-capacity contact type relay
that can switch DC12V, 5mA.
Motor sensor
connector (black)
Motor connector
(white)
single phase
200-240V
three phase
200-240V