12
For details, refer to “Brushless
-motor BMU
instruction manual”, appendix.
Circuit Protector
Control unit has built-in protective function against overload, overcurrent, overheat, etc. In emergency,
control unit trips.
For details, refer to “Brushless
-
motor BMU instruction manual”, appendix.
NOTE: 1. When control unit trips, immediately set RUN/STAND-
BY switch to “STAND
-
BY” position and
NOTE: 1.
turn off power supply. Before restarting machine, carefully check for cause of trip and ensure it
NOTE: 1.
is removed.
2. For increased safety, separately install overcurrent protective device on power source side.
1. Be sure to confirm that the power source voltage is within the rated voltage range,
1.
before switching ON the power source.
1.
(Voltage exceeding the rated voltage could cause fuming, abnormal noise, etc.)
2. Be sure to start and stop the conveyor with RUN/STAND-BY switch. When starting and
1.
stopping the conveyor frequently in a short period (tact operation etc.), it is impossible to
1.
start/stop the machine by turning on/off the power supply. In this case be sure to start
1.
and stop the machine by external signals. (Brushless-motor variable-speed type is
1.
different from speed controller’s, and the power supply will trip.) Do not start and stop
1.
the conveyor excessively frequently. It may cause machine failure or shorten its service
1.
life.
3. The RUN/STAND-BY switch of control unit is not for turning the power on and off.
1.
When leaving the conveyor unused for a long period, make sure that the mains is off.
4. Do not run the conveyor at excessively low speed for a long period, or start and stop the
1.
conveyor excessively frequently. These may cause machine failure or shorten its service
1.
life.
5. Do not touch the inverter radiator of side of control unit, and do not allow any material
1.
to touch it, because of its high temperature.
6. Use the control unit within the permissible range of ambient temperature (from
–10℃ to
1.
+40℃). Avoid freezing.
7. Pay special attention not to allow any foreign matter (dust, iron powder, etc.) to get into
1.
the control unit.
8. Operating the motor using the inverter could cause noises from the inverter I/O cables,
1.
motor, etc. Keep in mind that these could interfere with the correct operation of other
1.
electronic devices. (In this case, noises and their effects can be suppressed to some
1.
extent by providing the inverter I/O with a filter or otherwise shielding the power cable.)
Caution When Using Brushless-motor
fig. Control unit operating panel
Rotation direction switch
Display
Speed control
Front panel (Tool-less removal type)
RUN
/
STAND-BY switch
Mounting hole (It's located under
the front panel.)
Содержание S-CON MINI SLIM
Страница 1: ...1 S CON MINI SLIM OPERATING AND SERVICE MANUAL...
Страница 7: ...7 2 COMPONENT NAMES HEAD DRIVE TYPE CENTER DRIVE TYPE...
Страница 19: ...19 MEMO...