![Sanken NS-4A003-B Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/sanken/ns-4a003-b/ns-4a003-b_instruction-manual_809248042.webp)
-41-
Code
Function Name
Data Content
Setting
resolution
Factory
preset
1513
Relay contact output
Selection
0: Alarm contact
1: In operation 1
2: Undervoltage
3: End of simply scheduled operation
4: In operation 2
5: Frequency matching (1
st
speed frequency)
6: Frequency matching(1
st
~
16
th
speed frequency
)
7: Frequency approach
8: Overload alarm level setting signal (the value of
F1704
)
9: Electric thermitor pre-alarm signal
(
80% of electric
thermitor
)
10
:
Radiator overheat pre-alarm signal
13
:
Excitation and DC braking signals
14
:
Lower frequency limit matching signal
15
:
Upper frequency limit matching signal
16
:
Servo on ready signal
17
:
Zero servo completion signal
18
:
FR signal 19
:
RR signal
20
:
2DF signal 21
:
3DF signal
22
:
5DF signal 23
:
9DF signal
24
:
AD2 signal 25
:
AD3 signal
26
:
JOG signal 27
:
MBS signal
28
:
ES signal 29
:
RST signal
32
:
Discharge resistor on signal
36
:
Overload alarm level setting signal (Including in
Acceleration/Deceleration)
43
:
Low speed detection signal
48
:
Forward run detection signal
49
:
Reverse run detection signal
1
0
1518
Low speed matching
Level
0
~
2000rpm
1rpm
100
1519
Low speed matching
Range
0
~
100rpm
1rpm
10