background image

Your SANIJET Pipeless Whirlpool Bath is designed to be filled with 
fresh  water  then  drained  after  each  use.  Certification  by  NSF 
International ensures that your Pipeless System can be effectively 
cleaned  and  disinfected  by  simply  following  SANIJET’s  Pure 
Disinfection Protocol on Page 15.

COMManD PaD DESCRIPTIOn

A detailed description of your system’s command pad operation 
can be found on the following pages:

•  Single Bather Signature and Designer “Elite” Spa Baths
  (Pages 6-7)
•  Two-Person Signature and Designer “Elite” Spa Baths
  (Pages 8-9)
•  Designer “Essential” Spa Baths (Page 10)

WaTER LEVEL

Close the drain and fill the bath until the water level is at least 
2”  above  the  jets.  Operating  the  system  without  water  may 
damage  the  jet  assemblies.  Never  attempt  to  fill  above  the 
bottom of the overflow.

BaTH aDDITIVES

Bath  additives  (including  oil  based  products)  can  be  used  in  a 
SANIJET Pipeless Whirlpool Bath, since their residue can be easily 
cleaned. CAUTION: Use only low foaming additives.

CLEanIng YOUR SanIjET PIPELESS WHIRLPOOL BaTH:

WARNING: Unless thoroughly cleaned after each use, bath residue 
will  buildup  within  the  system  and  on  the  surface  area  of  any 
whirlpool  bath,  which  can  promote  the  growth  of  bacteria.  To 
maintain  your  SANIJET®  Pipeless  Whirlpool  Bath  at  a  maximum 
level  of  hygiene,  thoroughly  clean  the  tub  shell  and  jets  after 
each use with a nonabrasive antibacterial cleaner, rinse and dry. 
NEVER use abrasive household cleaners on any SANIJET® Pipeless 
Whirlpool Bath. If you use an anti-skid rubber mat in your whirlpool 
bath, remove it after every use to properly clean the tub surface 
and to avoid harm to the surface finish.

IMPORTANT!  TOTAL  DISINFECTION  REQUIRES  TWO  DISTINCT  STEPS: 
Cleaning and Disinfection.

PREPARATION & CLEANING

a.  Drain the bathing well of all water.

b.  Remove  and  disassemble  the  jet  assemblies  and  place 

them in the sink or other basin suitable for cleaning. 

c.  Use a non-abrasive antibacterial cleaner to clean the bathing 

vessel, jet cases, drain stopper and overflow mechanism–rinse 
with fresh water.

DISInFECTIOn

a.  Spray the surface area of the jet assemblies and bathing vessel 

until thoroughly coated with an EPA–registered disinfectant.

b.  Allow  to  set  for  the  required  disinfection  contact  period 

(refer to manufacturer’s specifications) then rinse surfaces 
with fresh water.

REaSSEMBLY

a.  Dry the jet assemblies and bathing vessel.

b.  Reinstall  the  jet  assemblies  by  aligning  with  jet  case  at 

10  o’clock  position.  Maintain  even  pressure  and  rotate  jet 
assemblies clockwise to lock them in place.

nSF CERTIFICaTIOn:

 NSF International confirmed that SANIJET’s 

Pipeless system can be completely cleaned and disinfected, even 
if system cleaning has been neglected.

REPAIRS

TUB SURFACE   Minor scratches can be easily removed. Immerse 
600-grit wet/dry sandpaper in water and lightly sand the area. 
Repeat  sanding  with  1000-grit  wet/dry  sandpaper  and  water. 
To  restore  the  surface  gloss,  use  Gel-Gloss®  (found  at  most 
hardware  stores).  If  Gel-Gloss  is  not  available  use  automotive 
rubbing  compound  followed  by  an  application  of  automotive 
paste wax. Major scratches and gouges will require professional 
refinishing. Contact SANIJET’s customer service department for 
specific instructions.
NOTICE: NO OTHER ITEMS ARE OWNER SERVICEABLE.

SUnLIgHT  EXPOSURE:

  In  order  to  prevent  discoloration  of  the 

acrylic finish, limit the exposure of the bath to direct sunlight.

TROUBLESHOOTING

If system will not operate: Check the remote GFCI circuit breaker 
to make sure it is in the ON position. Reset the GFCI if necessary.

nOTICE

Abnormal operation of the whirlpool bath functions may be the 
result  of  a  power  outage  or  poor  quality  power  service  in  your 
area. The circuit breaker, which supplies electrical power to the 
whirlpool bath, should be reset prior to placing a service call.

WaTER LEakagE

Call a plumber to determine the source of the leak. If the leak is 
from the pipeless whirlpool system, contact SANIJET’s customer 
service department for specific instructions.

Pipeless Whirlpool Bath

Operating Instructions

05

Содержание Elite Series

Страница 1: ...Spa Bath Owner s Manual Signature Collection Designer Collection Elite Designer Collection Essential TO BE REMOVED FOR USE BY THE OCCUPANT ...

Страница 2: ...e proceeding any further please take a few minutes to complete the warranty registration card enclosed in your Owner s packet and submit it to us at the address provided on the form Your SANIJET Pipeless Whirlpool Bath has been designed to provide you with safe and soothing hydromassage and to serve as a hygienic bathing appliance As you read along you will become familiar with the features of you...

Страница 3: ...and Pad Functions Two Person Spa Baths 3 Zone 08 Command Pad Functions Two Person Spa Baths 2 Zone 09 Command Pad Functions Designer Essential Spa Bath Command Pad 10 Pipeless Whirlpool Bath Installation Instructions 11 Electrical Requirements 12 Typical Installations 13 Plumbing 14 Sanijet Pure Pipeless Disinfection Protocol 15 Warranty Residential 16 Warranty Commercial 17 Customer Service Back ...

Страница 4: ...FCI should be provided by the electrician and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner there is a ground fault indicating the possibility of electrical shock DO NOT USE THE UNIT Have the problem corrected by a qualified service representative o...

Страница 5: ...ve antibacterial cleaner to clean the bathing vessel jet cases drain stopper and overflow mechanism rinse with fresh water DISINFECTION a Spray the surface area of the jet assemblies and bathing vessel until thoroughly coated with an EPA registered disinfectant b Allow to set for the required disinfection contact period refer to manufacturer s specifications then rinse surfaces with fresh water RE...

Страница 6: ... 1 setting press the MEMORY 1 button for less than 1 second MEMORY 2 Button To store your MEMORY 2 setting press and hold the MEMORY 2 button until the MEMORY 2 LED Indicator turns ON to acknowledge the setting has been stored To recall the MEMORY 2 setting press the MEMORY 2 button for less than 1 second 9 Pre Programmed Massage Modes All 6 Jet models have three pre programmed massage modes LINEA...

Страница 7: ...Indicates the system is ready to operate 2 OFF Button Turns the jets OFF and returns the system to STANDBY 3 LIGHT Button Used to control the optional mood light Press the Light button to turn on the mood light The light displays 7 vivid colors and 2 sequencing settings To change the light color press the Light button to turn it off and after one second press it again to turn it on The color seque...

Страница 8: ...splays the water flow of the BACK MID BACK jets 8 PULSE Button Pulsates the water flow and simultaneously allows individual jet pair control via the BACK MID BACK buttons This function allows all jets any two jet pairs or any single jet pair to pulse while the non pulsing jet pairs can be set at High or Low speed or turned OFF 9 Pre Programmed Massage Modes All three zone models have three pre pro...

Страница 9: ... of the buttons is pressed for less than one second the system will automatically increase or decrease the water flow of the selected jet pair 7 Jet Flow LED Indicators Displays the water flow of the BACK jets 8 PULSE Button Pulsates the water flow and simultaneously allows individual jet pair control via the BACK buttons This function allows all jets or either pair to pulse while the non pulsing ...

Страница 10: ...ose High Low Off Simply press the button on the command pad to turn on All Jets to their highest flow setting Press the button a second time to adjust All Jets to the low flow setting Press the button a third time to turn the system Off 20 minute timer All Designer Essential Spa Baths are equipped with a 20 minute timer that will turn the system Off after 20 minutes of continuous operation ...

Страница 11: ... do not remove the protective sheet of plastic from inside the bath 6 Immediately upon receipt inspect the tub shell and operating system for any obvious damage BEFORE installing Should inspection reveal any damage or defect in the finish do not install the bath SANIJET s responsibility for shipping damage ceases upon delivery of the product in good order to the carrier Refer any claim for damage ...

Страница 12: ...ions should be performed by a licensed electrician The tub obtains electrical service via an internal power cord and is left unterminated in the electrical junction box located on the side of the tub The junction box also provides an external lug connector to accommodate a 8 AWG solid bonding conductor ground wire See Illustration 1 The required electrical connections to the tub are as follows 1 T...

Страница 13: ...em component clearance information for your particular model please contact SANIJET toll free at 877 934 0477 SERVICE ACCESS The system does not require an external access panel for service Access to the jet motors the control electronics and the electrical service connections is accomplished from inside the tub The command pad located on the side of the tub provides an internal panel through whic...

Страница 14: ...o the bath unit or for water damage which might occur due to improper shower installation or use CLEANING THE BATH UNIT AFTER FINAL INSTALLATION To avoid dulling and scratching the surface of the bath never use abrasive cleaners A mild liquid detergent and warm water will clean soiled surfaces Remove spilled plaster with a wood or plastic edge Metal tools will scratch the surface Spots left by pla...

Страница 15: ...approximately 5 minutes when using Dispatch Hospital Cleaner Disinfectant with Bleach The SANIJET Pipeless Jet System does not require a fill and drain cycle during disinfection for improved water conservation For applications requiring quick cleaning between treatments we recommend a second set of clean jet assemblies for quick replacement IMPORTANT Always refer to your state and local guidelines...

Страница 16: ...hardware light bulbs or fading from exposure to direct sunlight b failure damage or defect caused by any of the following after the product leaves SANIJET s factory mishandling abuse misuse neglect accident or natural disaster normal wear and use that does not affect the product s function failure to maintain the product as recommended by SANIJET See Owner s Installation manual or c any part that ...

Страница 17: ...from exposure to direct sunlight b failure damage or defect caused by any of the following after the product leaves SANIJET s factory mishandling abuse misuse neglect accident or natural disaster normal wear and use that does not affect the product s function failure to maintain the product as recommended by SANIJET See Owner s Installation manual or c any part that has been altered or tampered wi...

Страница 18: ...garding and will not be responsible for any code compliance 6200 Maple Avenue DALLAS TEXAS 75235 877 934 0477 SANIJET COM REV101123 C P S R U NSF Protocol P182 Pipeless Hydrotherapy Jets Listed by IAPMO Research and Testing Inc as meeting the requirements of the Uniform Swimming Pool Spa and Hot Tub Code Standard for Hydromassage Bathtubs UL 1795 Standard for Hydromassage Bathtub Appliances CSA C2...

Отзывы: