22
4. Upon completion stick the replacement rating plate sticker on the under side of the hob.
5. Replace the rubber seal (if removed) and the control.
When the setting is right check regulation by quickly rotating the control from the maximum to the
minimum delivery position. The flame must not go out and remain stable throughout the range.
Burner Configuration Table
Gas Category
G30/31
G20
Normal Pressure (mbar)
28 – 30/37
20
Extra Large Burner
Injector Diameter (mm)
0.90
1.21
Nominal Rating (W)
3100
3100
Consumption
225/222 gr/h
295 lt/h
Large Burner
Injector Diameter (mm)
0.83
1.17
Nominal Rating (W)
2800
2800
Consumption
204/200 gr/h
267 lt/h
Standard Burner (front right)
Injector Diameter (mm)
0.58
0.85
Nominal Rating (W)
1400
1400
Consumption
102/100 gr/h
133 lt/h
Standard Burner (back left)
Injector Diameter (mm)
0.68
0.98
Nominal Rating (W)
1750
1750
Consumption
127/125 gr/h
167 lt/h
Small Burner
Injector Diameter (mm)
0.51
0.75
Nominal Rating (W)
1000
1000
Consumption
73/71 gr/h
95 lt/h