SET-UP AND CODE DESCRIPTION (CONTINUED)

 

        

Closed Door Data Retrieval Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Closed 

Door Data Retrieval Mode by displaying “

” where “

” is the password. Pressing 

selection button number one while the digits are flashing will change the current password. 

The available digits are 0-6. (

See note below

.) Pressing selection button two will save the 

change and advance to the next digit. In order to save the password and exit the mode, 

press selection button two while the last/fourth digit is flashing.

Note:

  

If one of the digits in the password is “0” this feature will be disabled since selection 

button “0” does not exist.

 

Note:

  This feature is not available when the vend price is set to “0.00”.

 

        

Language Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Language 

Mode by displaying the currently assigned language. The available languages are 

 – 

English, 

 – French, 

 – German,   – Italian, 

 – Portuguese, and 

 – Spanish. 

Pressing selection button one will toggle though the language options. If selection button 
two is pressed, the display will save the language change and return the display to 

.

 

        Clock Setting Mode

If selection button two is pressed at the “

” prompt, the controller will enter the Clock 

Mode which allows you to set the clock on the control board. This field must be set in order 

to operate any modes associated with the time. Pressing selection button two while any of 

the options are displayed will enter you in to the clock setting options. Pressing selection 

button one will toggle you through the options. Pressing selection button three will exit this 

mode.

CLOCK SETTING OPTIONS

Current Year (Example:  2002)

Current Date (month, day)

Current Time (hours, minutes)

Daylight Savings Time 

Clock Control

Содержание V21 Series

Страница 1: ...1 06 2005 12 1 PROGRAMMING SECTION...

Страница 2: ...rvice mode as indicated in the following steps below The main service modes are indicated in white text and the sub modes are indicated in black text Example Time Date Setting Mode Year Setting Month...

Страница 3: ...settable MIS data will be displayed if no errors exist XXX will ash for approximately 30 seconds indicating the total number of units the machine has sold After 30 seconds XX XX will begin to scroll i...

Страница 4: ...f selection button two is pressed a pay out of the displayed value will be made Coins will continue to pay out as long as that selection button is held down EXAMPLE If selection button two is pressed...

Страница 5: ...roller into the Relay test mode which allows the user to test the lights compressor evaporator fans or the heater Upon entry into the rely test mode the display will read for the compressor test To sc...

Страница 6: ...paid sales This total is non resettable and begins when the discount feature is enabled Pressing selection button 1 will scroll through all of the selection buttons and display the value of the discou...

Страница 7: ...cription Meaning Force Select Force select enabled y or disabled n Bill Escrow Bill Escrow enabled y or disabled n Error Sold Out Indicator Error Sold Out indicator enabled y or disabled n Single Pric...

Страница 8: ...ered If the column number is steady it is not assigned to the selection button To exit this mode press selection button three FIGURE 3 SEL ST10 STS9 STS8 STS7 STS6 STS5 STS4 STS3 STS2 STS1 COL COL COL...

Страница 9: ...n two is pressed at the prompt the controller will enter the Language Mode by displaying the currently assigned language The available languages are English French German Italian Portuguese and Spanis...

Страница 10: ...me Hour associated with 2nd start time 2nd End Time Time lights turn back on Days associated with 2nd end time Hour associated with 2nd end time Refrigeration Mode Ifselectionbuttontwoispressedatthe p...

Страница 11: ...l turn on off with the activation of the compressor 1 Fan Mode 1 the evaporator fan will turn off 5 minutes after the compressor fan is turned off The second submode refers to the Periodic Defrost mod...

Страница 12: ...toggle between the following modes REFRIGERATION CONTROL SETTINGS Refrigeration control enabled 1 disabled 0 Start Time Time temperature rises 18 F 10 C Days associated with start time Hour associate...

Страница 13: ...ime when the discount will occur If selection button two is pressed at the prompt the controller will enter the Discount Setting Mode Upon entry into this program the display will show If selection bu...

Страница 14: ...button two is pressed at the prompt the controller will enter the Free Vend Enable Option Upon entry into this program the display will show the current setting Press selection button two Pressing se...

Страница 15: ...ver Ride Option Upon entry into this program the display will show the current setting for enable and for disable Pressing selection button one will toggle between y for enabled and n for disable Pres...

Страница 16: ...14 1 2 3 4 15 16 5 6 17 18 7 8 19 20 9 10 YEL VIO GRY PNK WHT BRN ORN BLU J2 5 6 7 8 1 2 3 4 RED ORN VIO BLK 2 4 6 8 J6 1 3 5 16 7 9 M3 GRY M4 PNK M5 RED M6 BRN M7 ORN M1 YEL M2 VIO M8 TAN 10 11 12 1...

Страница 17: ...FRIG HEATER OPTION W A R M CABINET WARM CABINET COLD CABINET WARM CABINET COLD VS2 C O L D TRANSFORMER PRIMARY 24 VAC WHT BLK NO 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 POWER DIST BOX LIGHT RELAY...

Страница 18: ...18 06 2005 NOTES 1 If the outer door is left open for over an hour the lights and compressor will become active In order to over ride this option press the door switch one time...

Отзывы: