20    S&C Instruction Sheet 765-510

Installing the Wildlife Disks

Before installing the wildlife disks, determine the proper 
placement of the disks on the switch blade and contact 
insulators.

On Upright 14.4-kV Omni-Rupter Switches 
(Porcelain and Cypoxy™ Insulators)

Install the wildlife disk to the bottom skirt root of the 
insulator on both the blade and contact ends of the switch. 
When the wildlife disks are properly installed, the disks 
will overlap slightly, as shown in Figure 17.

On Upright 25-kV Omni-Rupter Switches 
(Porcelain and Cypoxy™ Insulators)

Blade end of the switch

: Install the wildlife disk on the 

bottom skirt root of the insulator. 

Contact-end of the switch

: Count up two skirts from 

the base and install the wildlife disk to the insulator 
on the blade-end. When the wildlife disks are installed 
properly, they will be at approximately the same height. 
See Figure 18.

On Upright 34.5-kV Omni-Rupter Switches 
(Porcelain and Cypoxy Insulators)

Count up two skirts from the base and install the wildlife 
disks on the third skirt root from the base of the insulator 
on both the blade and contact ends of the switch. When 
the wildlife disks are properly installed, the disks will 
overlap slightly.

Figure 18. Wildlife disk placement on 25-kV Omni-Rupter 

Switches, upright mounting configuration. 

Contact 
end

Blade end

Disks at same 
height

Install two skirts 
from bottom skirt 
root

Insulator

Insulator

Install disk on 
bottom skirt root

Figure 17. Wildlife disk placement on 14.4-kV Omni-Rupter 

Switches, upright mounting configuration.

Contact end

Blade end

Disks overlap 
blade-end over 
contact-end

Insulator

Insulator

Install disk on 
bottom skirt root

Install disk on 
bottom skirt root

Installation

Содержание Omni-Rupter Series

Страница 1: ...n this Instruction Sheet 2 Proper Application 3 Warranty 3 Safety Information Understanding Safety Alert Messages 4 Following Safety Instructions 4 Replacement Instructions and Labels 4 Location of Sa...

Страница 2: ...n Do not assume the operating handle position necessarily indicates the Open or Closed position of the interrupter switch blades Upon completion of an opening or closing operation visually check the p...

Страница 3: ...ns of Sale Immediate Purchasers Outside the United States plus any special warranty provisions as set forth in the applicable product line specification bulletin are exclusive The remedies provided in...

Страница 4: ...ecautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If...

Страница 5: ...ther side and with blades in any position G 6580 2 B WARNING Lifting Instructions G 9377 C WARNING Lifting Instructions G 9379 D NOTICE Instructions for Connecting Conductors to Terminal Pads G 9391 E...

Страница 6: ...clothing in accordance with safe operating procedures and rules 4 SAFETY LABELS AND TAGS Do not remove or obscure any of the DANGER WARNING CAUTION or NOTICE labels and tags Remove tags ONLY if instru...

Страница 7: ...rlocks mounting bracket for interlock V1 V2 or V3 adds one two or three respec tively extra 6 foot 10 inch 208 cm lengths of pipe and includes the appropriate number of extra couplings and guides A de...

Страница 8: ...urations Upright upright with extra mounting pole clearance and inverted mounting configuration switches are provided with a single point lifting bracket permanently attached to the switch base See Fi...

Страница 9: ...e washers between the square washers and nuts to compensate for wood pole shrinkage and thus maintain fastener tightness Square and spring type washers are not included with the switch STEP 1 Drill tw...

Страница 10: ...base from the shipping skid e Slowly and carefully lift the switch to the proper mounting height f Guide the switch so the through bolts projecting from the utility pole slip into the holes in the sw...

Страница 11: ...ngs ONLY to the single point lifting bracket c Lift the switch as shown in Figure 3 until the lifting slings are just taut d Unbolt the switch base from the shipping supports e Slowly and carefully li...

Страница 12: ...the switch to the proper mounting height f Guide the switch so the through bolts projecting from the utility pole slip into the holesintheswitch spole mountingbracket The pole mounting bracket is pro...

Страница 13: ...nstallation Installing the Optional Pole Band STEP 4 Securethepole band optional tothemounting bracketontheswitch usingtheJ boltsprovided See Figure 6 Two 1 3 inch stiffening blocks are furnished to b...

Страница 14: ...ility to the couplings joining one or more lengths of pipe Before assembling a coupling back the piercing set screw out of the coupling so the tip does not protrude into the body of the coupling This...

Страница 15: ...e in accordance with the dimension shown on the erection drawing STEP 8 Pass the next section of vertical operating pipe up through the guide bearing and attach it to the universal coupling on the low...

Страница 16: ...the ground ing strap the end with the grounding connector attached to the foot bearing assembly If necessary to compensate for the taper of the wood pole and to keep the vertical operating pipe align...

Страница 17: ...handle when lowered fits into the open position slot Mark on the support plate the location of the open position stop plate Figure 12 The foot bearing assembly and operating handle assembly Foot bear...

Страница 18: ...ith insulated bases NOTICE S C recommends installing the Wildlife Protection option after the switch is secured to the utility pole Damage to the Wildlife Protection option may occur if lifting slings...

Страница 19: ...ting brackets STEP 16 Hook one end of the spring clip assembly into the lip on the edge of one side of the base cover See Figure 15 Bring the spring clip underneath the switch base and stretch it unti...

Страница 20: ...blade end When the wildlife disks are installed properly they will be at approximately the same height See Figure 18 On Upright 34 5 kV Omni Rupter Switches Porcelain and Cypoxy Insulators Count up t...

Страница 21: ...t up three skirts from the live parts and install the wildlife disk to the insulator on the blade end When the wildlife disks are installed properly they will be at approximately the same height See F...

Страница 22: ...witch See Figure 21 Then insert the locking tabs of one half of the disk into the open slot on the other half to create a secure overlapping fit Repeat the procedure on the opposite side of the disk W...

Страница 23: ...king tab firmly into place Both tabs should protrude through the open slot as shown in Figure 22 on page 22 d Repeat Steps 17 a through 17 c to install the wildlife disks on the insulators on the cont...

Страница 24: ...alues are shown in Tables 1 and 2 Table 1 Maximum Single Side Dead End Loading for Steel Base Switches Mounting Configuration Pounds per Conductor 14 4 kV 25 kV 34 5 kV Upright 2000 2000 1500 Upright...

Страница 25: ...em in their respective connectors d Attach the connectors to the terminal pads Allow the articulating terminal pad to settle naturally with the weight of the conductor For other types of connector fol...

Страница 26: ...vel locking disc and interlock bracket If provision only for a key interlock is specified the interlock will not be included See Figure 28 Assemble with the operating handle assembly as follows If nec...

Страница 27: ...use the interlock bolt to position thelockingdiscsotheboltenterstheclosed position slot in the disc and will enter the open position slot when the switch is in the Openposition Holdthelockingdisc inc...

Страница 28: ...structions S C Instruction Sheet 1045M 510 STEP 21 Open and close the interrupter switch by swinging the handle slowly through its full travel Make sure the following conditions exist a With the opera...

Страница 29: ...er shunt arm will be released and will quickly snap back to its Closed position and reset for the next operation See Figure 33 c Slowly close the switch The following conditions should be met The inte...

Страница 30: ...sustained during shipping or storage Contact the nearest S C Sales Office for assistance NOTICE Omni Rupter Switches specified with the optional harsh environment contacts catalog number suffix C have...

Страница 31: ...Figure 38 Lower the handle into the open stop plate Secure the handle with a padlock or retaining device according to standard system operating procedures and safety practices Make sure all three pole...

Отзывы: