8
The web configuration appears as follows, Figure . The device can be configured using our Serial
Manager utility also, for more information, refer to Serial Manager’s manual.
Figure 2
On the left side, a menu-tree appears with all the modes and options available; while on the right side
of your screen the contents of each mode/option will be displayed in a graphical state. It is also worth
noting that as a first step to view your device’s overall settings, you should use Serial Manager© (the
utility provided in the CD). There will be however, some buttons which will be present during almost
each section.
2.6 Factory Default Settings
Upon arrival, the device will be set as follows:
Parameters
Default Values
LAN 1
IP Address
10.0.50.100
Gateway
10.0.0.254
Subnet Mask
255.255.0.0
LAN 2
IP Address
192.168.1.1
Gateway
192.168.1.254
Subnet Mask
255.255.255.0
User Name
Admin
Password
null (leave it blank)
COM
RS-232 (RS-422 if RS-232 is unavailable),9600, None, 8,1,No Flow
Control
COM Link Mode
Mode: RAW, Type: TCP Server, Listen port 4660, Filter=0.0.0.0