![Samyung SRG-315DN Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/samyung/srg-315dn/srg-315dn_user-manual_3786647037.webp)
36
Chapter 10. How to use SD-250(Alarm box)
10.1. Distress transmitting
(1) If you press 'Distress key' (Red Button) for 3
sec., it alarms for 3 seconds.
After that, the red light is turned on with bip-sound.
While Distress Key is blinking, transmitting is
started to work and location of disaster, time, ship's
ID are sent to DSC 6 CH in order.
If there is no answer, it does sending till getting an
answer through CH1 to CH 6.
(2) In order to stop the transmitting, press the
'Reset key'.
If distress signal is sent by mistakes, contact to
marine police or station, SAR.
10.2.
In case of receiving distress signal
(1) Distress LED blinks and sounds 'bip'.
Check contents displayed on the screen and press
Reset key to stop.
10.3. Operation by DC (Battery)
(1) If AC power is turned off, POWER LED is
blinking with "Bip-" sound and presses the Reset
key to stop the sound.
(2) POWER LED keeps blinking while the equipment
is operated by DC power.
Chapter 11. How to use SP-1250ADC
11.1. Specification
(1) Input : AC110V / AC220V Conversion Type
(Basis AC220V)
(2) Output : DC24V 50A AVR
(3) Charging current: 20A (Max)
11.2. Input power shift
In case of AC Power stopping, the buzzer is ringing
and LED green light of AC OFF is on. In
order to stop the buzzer's ringing, you can turn to
OFF in the switch of ALARM.
11.3. How to Charge
(1) In case of transmitting SSB, it doesn't be
charged.
(2) There is AUTO / OFF / NORMAL in a switch of
the Charger.
(3) AUTO = in a long-time charging and it turns to
auto-off when it is completed.
In charging, the LED of CH turns on a light.
In less 23 voltages, auto-charged and finished for
charging in less 0.5 A.
(4) OFF = Not charging. (Middle of Switch)
(5) NORMAL = Sometimes charge it in the mode.
(6) In case of checking the charged current, the
switch of CURRENT is turned to CHARGER.
In case of transmitting SSB, the switch is turned
to TX in order to check the current.
REFERENCE: SP-1250ADC is designed to connect
with SSB SRG-3150D only and it is charged as own-
battery power according to the regulation of IMO
(GMDSS).
If it is connected with other SSB equipment, you
should intercept the charging-circuit in SP-1250ADC
and use the high-capacity charging.
11.4. In case of over current
In case of being over than 45A current, the LED
red light of OVER CURRENT is on and the buzzer is
ringing. On this occasion, intercept the Power
Switch AC / DC for over than 1 minute and turn the
Power on after deleting the occasion.
Содержание SRG-315DN