Diagnosis
The chart explains the general symptoms of breakdown and solutions to it.
User should not disassemble equipment. The attempt may degrade the function of
equipment or shorten the life of it. Therefore you take it to the professional engineer (A/S
Center)
AS Center ☏ : 051-601-5570~5574, +82-51-601-5570~4
Symptom
Solution
Power doesn’t turn on
Check the power connector has been
connected firmly.
Check the power or fuse..
Does not receive GPS satellite information
Check the connection of GPS antenna,
Antenna cable and connectors.
Check that the [GPS Port Setup] has been
set as 『Internal.
Display is Unstable or white stripe appears
Display color changes
Check the connection condition of LCD
connector.
Clean the LCD connector’s point of contact.
The position value error is large
Check if datum has been selected to
‘WGS84’.
If you have set latitude, longitude, correction
function, set the value back to 0.
Vessel’s speed value error is large
Adjust the smoothing function to set the
value up for the vessel which is slow, and set
the value low for the vessel which is fast.
Hard to distinguish the fish or seafloor due to
the low gain.
Adjust the gain
Multiple seafloor appears
Adjust the gain
The record of fish or seafloor gets cut or
uneven.
This may be due to the vessel’s rolling,
pitching or bubbles made by vessel’s screw.
Transmitting line does not appear.
If the range [Position setup] has not been
set to ‘0’, adjust it to ‘0’.
Содержание Nf100
Страница 1: ...User Guide 1...
Страница 2: ...User Guide 2...
Страница 4: ...User Guide 4...
Страница 16: ...User Guide 16 REM 350...
Страница 49: ...User Guide 49 AIS Vessel Information 1 AIS Vessel Information 2 AIS Vessel List AIS Vessel Safety message...
Страница 64: ...User Guide 64 4 9 Other settings Press long then select Others...
Страница 81: ...User Guide 81...
Страница 83: ...User Guide 83...
Страница 84: ...User Guide 84...
Страница 85: ...User Guide 85...