background image

Door Lock Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 7 (Sky/
Blue)

 

When Door is Locked or Unlocked 
there is a pulse of 120VAC for a few 
milliseconds.

 

With Power Off, the resistance  
between these pins will be between 
47 - 57

 

Door Unlock Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 8 
(White)

 

When Door is Locked or Unlocked 
there is a pulse of 120VAC for a few 
milliseconds.

 

With Power Off, the resistance  
between these pins will be          
between 47 - 57

 

Drain Motor Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 6 
(Black)

 

120VAC with the pump On and 0VAC 
with the pump off

 

Power Off, the resistance should be 
13.9

 

Water Valve Check

 

Test 1

 

Test 2

 

Connector CN7 Pin 2 (Black) to CN10 Pin 4 (Pink), 
Pin 2 (Red) , Pin 1 (Blue)

 

120VAC with the Valve On and 0VAC 
with the Valve off

 

Power Off, valve resistance is from 
1202

 - 1245

 

Error Type  

Error Mode  

Details  

LED LCD 

                                                         
Water Level Sensor 

               
LE       

 

Check the Hose where the sensor is connected, may be loose, 
pinched, damaged or clogged. Also check the sensor it may be 
disconnected or defective. The Main PCB may also be defective  

                                                 
Motor Drive  Error or 
Hall Sensor error  

 

         
3E 

 

Check the  motor drive connector, it may be loose. The hall sensor 
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose 
or damaged. The drum might be overloaded from too many 
clothes or the relay or PCB  might be defective.      

 

E3 

bE 

                                              
Water Supply 

Error 

                        
nF   

 

Check the water valve wiring harness. 

Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly. 

Check for reversed fill hoses 

Check water temperature, if sensed as higher than 50 

˚

C in the 

Wool or Lingerie cycle it will create error. 

Check the relays, if they operate correctly replace the Main PCB. 

Fill Hoses Reversed  nF1 

 

Correct Hot/Cold hose connections 

System Error 

SF1 
SF2  
SF3 

 

Replace PCB

 

4

Содержание WF209ANW/XAA

Страница 1: ...rt Pause while the code is displayed to view the number of cycles since the error occurred Peripheral Main PCB input Tests 1 Select Extra Wash Then turn the Dial so that the Heavy is turned on Next press the Start Pause Key The Water Temperature will be displayed in Fahrenheit 2 Select Extra Wash Then turn the Dial so that the White is turned on Next press the Start Pause Key The door status will ...

Страница 2: ...WF209 2 ...

Страница 3: ...at no water in the drum Operating Resistance Power off 2 5VDC Pin 8 Pink and Pin 7 Violet 22 24Ω Hall Sensor Check Test 1 Test 2 Connector CN8 Pin 4 Orange and Pin 2 Red ad ditionally Pin 4 Orange and Pin 3 blue Manually spin the drum to see the volt age change Power On N A 0Vdc or 3 75Vdc Motor Check Test 1 Test 2 Connector CN9 Pin 1 Blue Pin 2 White and Pin 3 Red Power Off 11 5Ω across Pins 1 2 ...

Страница 4: ...r Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign o...

Страница 5: ...e If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are i...

Страница 6: ...y the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the l...

Страница 7: ...40146A ASSY HOSE WATER DC97 15691A ASSY HOSE WATER DC97 15692A MANUAL BOOK DC68 02535A CAP FIXER DC67 00307A HOSE HANGER DC62 10278A When using non HE detergents or using too much detergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there will be leaks out of the detergent drawer and door Please advise con sumer of proper de tergent usage Valve...

Отзывы: