Washer Connector Checks WF209
CN5
1 AC Pwr (N) (Wht)
3 AC Pwr (L) (Blu)
CN7
2 Door Lock & Valve
common (to L)(Blk)
Water Temperature Thermistor Check
Test 1
Test 2
Connector CN 3 Pin 3 (White) and CN3 Pin 6
(Orange)
Operating voltage at Room temperature
-
Operating Resistance at Room
Temperature (Power off) discon-
nect CN3
2.5VDC (5VDC May indicate a connector
issue)
12-14k
Ω
Door Switch Check
Test 1
Test 2
Connector CN3 Pin 4 (Brown) and CN3 Pin 6
(Orange)
DC voltage Door Open, 0VDC Door
Closed
Operating Resistance with
power off
24k
Ω
Water Level Sensor Check
Test 1
Test 2
Voltage: Connector CN 3 Pin 8 (Pink) and CN3 Pin
5 (Orange) And Connector CN 3 Pin 7 (Violet) and
CN3 Pin 6 (Orange)
Resistance: Connector CN 3 Pin 8 (Pink) and CN3
Pin 7 (Violet)
Operating voltage at no water in the
drum-
Operating Resistance (Power
off)
2.5VDC
Pin 8 (Pink) and Pin 7 (Violet)
22- 24
Ω
Hall Sensor Check
Test 1
Test 2
Connector CN8 Pin 4 (Orange) and Pin 2 (Red) ad-
ditionally Pin 4 (Orange) and Pin 3 (blue)
Manually spin the drum to see the volt-
age change, Power On
N/A
0Vdc or 3.75Vdc
Motor Check
Test 1
Test 2
Connector CN9 Pin 1 (Blue), Pin 2 (White) and Pin
3 (Red)
Power Off 11.5
Ω
across Pins 1-2, Pins 1
-3, & Pins 2-3
N/A
A/C Power Check
Test 1
Test 2
Connector CN 5 Pins 1 (White) and 3 (Blue)
Power On 120VAC
N/A
CN9
1 Motor Pwr U Phase (Blu)
2 Motor Pwr V Phase (Wht)
3 Motor Pwr W Phase (Red)
CN10
1 Main Valve (Blu)
2 Hot Valve (Red)
4 Bleach Valve (Pnk)
6 Drain Pump (Blk)
7 Door Lock Close (Sky)
8 Door Lock Open (Wht)
CN8
(Hull Sensor)
1 +5 vdc (Pnk)
2 Sensor Signal (Red)
3 Sensor Signal (Blu)
4 Ground (Org)
CN1 & CN2
PCB Sub (Display)
CN3
3 Water Temp Thermistor (Wht)
4 Door Sw (Brn)
6 Water Temp Thermistor Gnd. (Org)
7 Water Level Sensor (Vio)
8 Water Level Sensor (Pnk)
3
Содержание WF209ANW/XAA
Страница 2: ...WF209 2 ...