background image

Error Type  

Error Mode  

Details  

LED LCD 

                             
Drain Error 

                         
nD                               

 

Check for Foreign material entering the pump or hoses.  

Check to make sure the wiring harness is connected properly. 

Check the water pump terminal . 

Check for freezing 

                         
Power Error  

                         
2E           
91           
92  

 

Make sure to check the operating voltage. (An error occurs when 
under or over voltage is supplied.)   Check whether a plug recepta-
cle is used. When the connecting wires are too small (extension 
cord use), a momentary low voltage may drop up to 10 V 

Main PBA fault (sometimes) 

PF 

 

Momentary Power Failure 

                                 
Communica-
tion Error 

AE 

 

Check the wire connections and terminal contacts between the sub 
and main PBAs. 

Check for disconnected wires. 

Check whether the sub PCB is short circuited because of moisture. 
If the main PCB’s communication circuit is faulty, replace it. 

                              
Switch Error 

(Main Relay 

Error)  

                         
E2           
15 

 

Check whether either the Power switch or a tact switch (any button)  
is stuck down. 

Check whether the service PBA holding screws are fastened too 
tight pinching the contacts 

If the main PBA switching IC on/off error has occurred, replace the 
main PBA. 

The “E2” error occurs if the main relay connections are incorrect. 
Check the connections. If there is no error in the connections, re-
place the main PBA  

                        
SR 

 

 

dS           
22 

(Before 

operation) 

 

Door Error 

dL           
18 

(During 

operation) 

 

 

LO            

(Unlock 

Fail) 

 

 

FL             

(Lock Fail) 

 

 

 

 

Check the door switch and latch alignment .  

Check the latch for damage 

Check the wiring harness to the latch.  

Check the door switch. Replace if faulty. 

Check the main PBA door sensing circuit. Replace if faulty. 

Finally verify he operation of the Main PCB 

EEPROM 
Fault. 

11 

 

Go to “EEPROM Clear Mode” If display shows “FAiL”, Replace Ma-
chine Control Board 

5

Содержание WF209ANW/XAA

Страница 1: ...rt Pause while the code is displayed to view the number of cycles since the error occurred Peripheral Main PCB input Tests 1 Select Extra Wash Then turn the Dial so that the Heavy is turned on Next press the Start Pause Key The Water Temperature will be displayed in Fahrenheit 2 Select Extra Wash Then turn the Dial so that the White is turned on Next press the Start Pause Key The door status will ...

Страница 2: ...WF209 2 ...

Страница 3: ...at no water in the drum Operating Resistance Power off 2 5VDC Pin 8 Pink and Pin 7 Violet 22 24Ω Hall Sensor Check Test 1 Test 2 Connector CN8 Pin 4 Orange and Pin 2 Red ad ditionally Pin 4 Orange and Pin 3 blue Manually spin the drum to see the volt age change Power On N A 0Vdc or 3 75Vdc Motor Check Test 1 Test 2 Connector CN9 Pin 1 Blue Pin 2 White and Pin 3 Red Power Off 11 5Ω across Pins 1 2 ...

Страница 4: ...r Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign o...

Страница 5: ...e If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are i...

Страница 6: ...y the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the l...

Страница 7: ...40146A ASSY HOSE WATER DC97 15691A ASSY HOSE WATER DC97 15692A MANUAL BOOK DC68 02535A CAP FIXER DC67 00307A HOSE HANGER DC62 10278A When using non HE detergents or using too much detergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there will be leaks out of the detergent drawer and door Please advise con sumer of proper de tergent usage Valve...

Отзывы: