Samsung Electronics
3-1
3. Alignment and Adjustments
3-1 Indoor Display Error and Check Method
■
Error detection and reoperation
■
●
If error occurs during the operation, badness is indicated by LED flickering and all operation is stopped except LED.
■
●
When reoperating by remote control and switch determine the error mode after normal operation.
■
Indoor unit LED lamp display at error detecting
Error type
LED lamp display
Remark
Power reset
X
◑
X
X
X
X
Error of temperature sensor
in the indoor unit (Open/Short)
X
X
◑
X
X
X
Displayed on appropriate
indoor unit which is operating
Error of heat exchanger sensor
in the indoor unit
X
◑
◑
X
X
X
Displayed on appropriate
indoor unit which is operating
Error of the outdoor temperature sensor
Error of the condensor temperature sensor
Error of the discharge temperature sensor
X
◑
X
◑
X
X
Displayed on appropriate
indoor unit which is operating
Displayed on outdoor unit
Indoor and outdoor unit time out
Abnormal data reception more than 60 packet
Indoor unit is not connected
Communication error between the outdoor unit
Main-Inverter Micom(After 1 minute of Main-Inverter
detection)
X
X
◑
◑
X
X
Error of indoor unit :
Displayed on the indoor unit
regardless of operation
[Self diagnosis]Power voltage detection between
indoor and outdoor unit communication cable
[Self diagnosis]Outdoor unit refrigerant leakage
(Gas leak)
[Self diagnosis]Outdoor fan restriction error
[Inverter]Inverter compressor operation failure
[Inverter] DC peak error
[Inverter]DC Link voltage 150V or less, 410V or more
[Inverter] Compressor rotation error
[Inverter]Electric current error
[Inverter]DC Link sensor error
[Inverter]EEPROM READ/WRITE error
[Inverter]Inverter zerocrossing error
Setting the outdoor unit capacity option error
X
X
◑
◑
◑
X
Error of setting option switches for optional
accessories
X
X
◑
X
◑
X
EEPROM error
X
◑
◑
◑
X
X
EEPROM option error
◑
◑
◑
◑
◑
◑
● :
On,
◑ :
Flickering,
X :
OFF
◆
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
25890A(1)_1.indd 1
2006-04-14 ソタネト 2:21:50
Содержание UH052EAV
Страница 36: ...MEMO Samsung Electronics 5 4 ...
Страница 68: ...Samsung Electronics 7 3 This Document can not be used without Samsung s authorization UH070EAV Wiring Diagram ...
Страница 70: ...Samsung Electronics 8 2 Outdoor Unit This Document can not be used without Samsung s authorization 8 2 ...
Страница 104: ...Samsung Electronics OUTDOOR FAN B D DIODE IPM DC_LINK CAP SMPS IGBT 13 3 UH052EAV Block Diagram ...
Страница 105: ...13 4 Samsung Electronics UH070EAV OUTDOOR FAN IGBT DIODE IPM DC_LINK CAP SMPS B D Block Diagram ...