TroubleShooting Manual
2
© SAMSUNG Electronics Co., Ltd.
Troubleshooting
1.
Change threshold alarm max-call value.
2.
Change system-wide max-call count.(default max-call count is
configured to system maximum value)
To change theshold alarm max-call value, use call-admission threshold alarm
max-call CLI command in global configuration command mode. To check
current value use show running-config command.
call-admission threshold alarm max-call min <value> maj <value>
no call-admission threshold alarm max-call
min <value>: Is the percentage of current call count against max call count
that minor alarm would be created. Default value is 70. Range is 1~99.
maj <value>: Is the percentage of current call count against max call count
that major alarm would be created. Default value is 80. Range is 1~99.
To change max call used as the basis, use ‘call-admission max-calls’ command
in global configuration command mode. To check current value use show
running-config command.
call-admission max-calls <value>
value: Designates max calls that is admitted and a number of 1~20,000 can be
used.