Ubigate iBG2016 TroubleShooting Manual
© SAMSUNG Electronics Co., Ltd.
1
TroubleShooting Manual
Max call limit alarm
It is an alarm created when a certain percentage is reached on the basis of pre-
configured max call and max call threshold alarm.
Symptoms
On the iBG2016 system, following event will be occurred.
#Feb 09 11:57:45 critical EVENT Exceeding a major
threshold of the system max call limit RAISE
#Feb 09 11:58:28 informational EVENT Exceeding a major
threshold of the system max call limit CLEAR
#Feb 09 11:59:23 error EVENT Exceeding a minor
threshold of the system max call limit RAISE
#Feb 09 11:59:25 informational EVENT Exceeding a minor
threshold of the system max call limit CLEAR
Possible Causes
Current call count is reached on pre-configured threshold alarm value.
−
Minor threshold limitation value = system wide max calls * minor
threshold alarm max-call / 100
−
Major threshold limitation value = system wide max calls * major
threshold alarm max-call / 100
Содержание Ubigate iBG2016
Страница 1: ......
Страница 22: ...TroubleShooting Manual 8 SAMSUNG Electronics Co Ltd This page is intentionally left blank...
Страница 24: ...EQNA 000044 Ed 00...