9
PORT TYPE: Setup type of port to use.
-PORT A: Connect the SCC-3100 controller.
-PORT B: Connect the speed dome.
-Control method
-Controller : Connect PORT A and controller with RS422/485..
Setup the SYSTEM ID corresponding to the connected SCC-3100.
(Refer to page 27)
-Speed dome : Connect PORT B and speed dome with RS422/485.
After moving SYSTEM
→
PTZ, setup protocol for each channel and the
ID for the speed dome. (Refer to page 78)
9
BAUD RATE : Setup the data transmission speed per second.
9
DATA BIT : Setup the data transmission bit.
9
PARITY BIT : Setup the error check method for data transmission.
9
STOP BIT : Setup bit to include when data transmission has been completed.
5.9.4 E-MAIL
The manager can verify details related to the generated event through the email.
9
E-MAIL CHECK : If turned [ON], E-MAIL notice function is activated.
9
to
.…
: Setup the E-MAIL address to receive a transmission if an event occurs.
..
Ex) to : [email protected]
9
SMTP SERVER : This is a standard protocal for transmitting e-mail and used to prevent
e-mail from spam mail. You must have a User ID for using e-mail.
Ex) SMTP SERVER : kornet.net
9
AUTHENTICATION: Used during user account registration.