INSTALLATION  

 

 

 

   

NOTES 

 

SHEET NO.          REV.       SEC.

 

 

 

 

 

     

XX102-10-00   503    

   4

 

 
 
 

KE12/KE24 Kollector Elite RAID Setup 

This procedure describes the setup of the KOL-RAID3 Series of Digital Video RAID Level 3 Storage System. 

Note: 

Vicon systems and components, like most electronic equipment, require a clean, stable power 

source. Voltage irregularities such as surges, drops, and interruptions can affect the operation of 
your equipment and, in severe cases, damage certain components. Vicon strongly recommends the 
use of line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems. 

 

Installation 

The KE Digital Video Recorder, Monitor and RAID3 Storage Sys-
tem must be connected and powered-on in a specific order to 
verify proper operation. The following steps must be done in or-
der. Refer to XX102-0X (where X is the major revision number 
between 0 and 9) for complete information on the KOL-RAID3 
Storage System. 
1.  Unpack the entire system. Do not connect any cables until 

instructed. If there are multiple RAID3 and Kollector recorder 
units, match the pairs in accordance with their labels. 

2.  Connect the Monitor to the back of the KE Recorder as 

shown in Figure 1a, beige connector to the left. Connect the 
proper end of the supplied SCSI cable to the SCSI connector 
as shown in the middle of Figure 1a. 

3.  Connect the remaining end of the SCSI cable to the SCSI 

connector on the rear panel of the RAID3 Storage System as 
shown in Figure 1b. 

4.  Connect the provided power cable to the Monitor and to an 

appropriate power outlet. Power-on the Monitor. 

5.  Verify the position of the 3 rocker switches on the rear panel 

of the RAID3 Storage System. They must set to the OFF po-
sition so the "O" side of the rocker is down against the panel. 
Figure 2 shows the 3 rocker switches in the ON position. 
With the 3 switches OFF, connect the provided power cable 
to the RAID3 Storage System and to an appropriate power 
outlet. Power-on the RAID3 Storage System by pushing the 
"I" side of the rocker switches in the order of the 2 horizontal 
switches first and the vertical switch last. The system will 
perform a boot routine for about 1 minute. 

6.  Connect the provided power cable to the KE Digital Video 

Recorder and to an appropriate outlet.

 

 
 

 

Copyright © 2003 Vicon Industries Inc. All rights reserved. 
Product specifications subject to change without notice. 
Vicon and its logo are registered trademarks of Vicon Industries Inc. 

Vicon Part Number 8009-8102-10-00 Section 4 Rev 503 

 

a. 

 

b. 

Figure 1 

SCSI Cable Connection 

 

VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 

TELE: 631-952-CCTV (2288)  FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) 

UK: 44/(0) 1489-566300  INFOFAX: 800-287-1207  WEB: www.vicon-cctv.com 

Содержание Kollector Elite KE12

Страница 1: ...n in the middle of Figure 1a 3 Connect the remaining end of the SCSI cable to the SCSI connector on the rear panel of the RAID3 Storage System as shown in Figure 1b 4 Connect the provided power cable to the Monitor and to an appropriate power outlet Power on the Monitor 5 Verify the position of the 3 rocker switches on the rear panel of the RAID3 Storage System They must set to the OFF po sition s...

Страница 2: ...t Panel Figure 4 Main Screen 8 With the RAID3 Storage System functional power on the KE unit The system will perform a boot routine for about 1 minute 9 When the KE Recorder displays the Main Screen shown in Figure 4 login as the appropriate opera tor level entering the correct Username and Password See details on setting up passwords in the KOL RAID3 manual XX102 10 00 Rev 503 KE12 KE24 Kollector...

Страница 3: ...ould appear as a number close to 500 750 or 1000 If the RAID letter does not appear this procedure needs to be repeated from the first step 13 RAID setup is complete Figure 6 Picture Database Utilities Screen Hard Drive Size s GB Drive Letters Physical Drive Type D CD RW E 120 GB F RAID G N A H N A D CD RW E 160 GB F 120 GB G RAID H N A D CD RW E 160 GB F 160 GB G 120 GB H RAID KE120 16 280 KE240 ...

Страница 4: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: