background image

GB-4

B. Camera movement key 

- PRESET
- PATTERN
- SCAN
- AUTO PAN

C. Alarm release key 

D. Joystick controller (UP/DOWN/LEFT/DOWN/AF/ZOOM)

The Pan/Tilt connected with Samsung Dome Camera or Receiver Unit
is moved to UP/DOWN/LEFT/RIGHT. Press the button on the top of
Joystick to control the Auto Focus. And use for the zoom control by
turning to the clockwise or counterclockwise. The function of UP/
DOWN/LEFT/RIGHT keys is controlled in the menu screen of the
connected controller. Press the button of the top to execute ENTER
motion.

E. Camera lens key 

- IRIS control (IRIS CLOSE/OPEN)
- FOCUS control (FOCUS NEAR/FAR)
- ZOOM control (ZOOM TELE/WIDE)

F. MENU key

This key is to go into the menu mode for the setup of various devices.

G. Device select key (MON/CAM/MUX/DVR)

This key is to select Camera, Monitor, DVR, MUX Number, or oth-
ers.

H. Number key (0~9), ENTER key, CLEAR key

This key is to select Camera, Monitor, DVR, MUX Number, Preset,
Pattern Number, or others. 

I. DVR control key (SEQUENCE, MODE)

- SEQUENCE : Executes the SEQUENCE function of DVR.
- MODE : Executes the partition screen selection function of DVR.

J. Jog shuttle 

- JOG : Is in use for Forward / Reverse Frame search in the playback     

mode of DVR.

- Shuttle : Executes the Play / Reverse Play / FF / REW functions in 

the playback mode of DVR.

K. DVR play key

- PLAY/PAUSE
- STOP
- FAST FORWARD
- REWIND
- RECORD

Back side 

L. DC 12V IN

DC 12V power input terminal.

M. RS-485

For RS-485 communication, it will be connected to the RS-485 termi-
nals of other system keyboards or controlling devices such as cam-
eras, DVR, and MUX. 

N. RS-232 

Connection port to adjust the system key board in a factory.

Chapter 2. Installation 

Installation Environment Setup

The following information is prepared for safe installation of the unit.
This unit can be placed on a flat table or installed in the rack. It
should not be used vertically or skew, but horizontally. The location
of the unit and the composition of wiring are very important in prop-
erly operating the system. When equipment is placed too close or if
ventilation is not properly done, system may not work properly, and
maintenance of the system may be difficult. In order to prevent sys-
tem failure and to reduce system shut-down by outside environmental
factors, air circulation in the system operating room, and the cover of
the unit must be fixed. Do not open the cover voluntarily because
high voltage within the unit may cause electric shock.

PHYSICAL & ENVIRONMENTAL
• Operating Temperature : 0 °C to 40 °C
• Temperature : -20 °C to 60 °C
• Operating Humidity : 20% to 85% (RH)
• Maintenance Humidity : 20% to 95% (RH)
• Power Supply : 12 VDC, 600mA (                    )
• Power Consumption : less than 3W

Caution
When system is operated, input voltage range must be within 10% of
nominal voltage, and power consent should be grounded. Heating devices
such as hair dryer, iron, refrigerator should not be used together. For safe
power supply, AVR (Automatic Voltage Regulator) is recommended.
The connector linked to this equipment can affect EMI, so it is recom-
mended to coil the CORE-FERRITE for use.

Cautions for Installation

• Be sure to turn the unit off before installing.
• Avoid shock or vibration since they may cause unit malfunction.
• Keep away from magnets, radio or TV to avoid magnetic damage.
• During or after installing the unit, be sure to maintain the area around the

unit clean.

• Place the unit on a flat surface and maintain temperature properly. Allow

15 cm of clearance between the rear panel and the wall.

• Be careful not to drop any conductive materials into the hole for ventilation
• When replacing built-in fuse, be sure to turn the power off, and unplug the

unit.

• Avoid locating the unit where direct sunlight will fall, and maintain it cool.

Keep tools and equipment away from people so that they would not be
hurt.

• If ignoring smoke or smell while using the unit, fire or electric shock may

occur. In this case, turn the power switch off immediately, and consult pro-
fessionals in the closest service center.

Содержание SSC-2000

Страница 1: ...System Keyboard SSC 2000 User s Manual GB F D ES I R P ...

Страница 2: ...defeat the safety purpose of the polarized or grounding type plus A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from ...

Страница 3: ...onnecting PC by RS 232 gb 7 Connecting Other System Keyboard gb 7 Basic System Diagram of SSC 2000 gb 7 Chapter 4 Instructions gb 8 Log in gb 8 Camera control gb 8 DVR control gb 11 MUX control gb 11 Chapter 5 MENU setup gb 12 MAIN MENU gb 12 KEYBOARD SETUP gb 12 RS 485 COMMUNICATION SETUP gb 12 RS 232 COMMUNICATION SETUP gb 13 CHANGE PASSWORD gb 14 CHECK PASSWORD gb 14 REGISTER NEW OPERATER gb 14...

Страница 4: ...ation of the unit and the composition of wiring are very important in prop erly operating the system When equipment is placed too close or if ventilation is not properly done system may not work properly and maintenance of the system may be difficult In order to prevent sys tem failure and to reduce system shut down by outside environmental factors air circulation in the system operating room and ...

Страница 5: ... it from being deviated when you connect it with the main body Chapter 3 Connecting with Other Equipment You can use the SSC 2000 system key board with a camera DVR MULTIPLEXER and the other equipments This chapter describes how to connect each equipment Connecting RS 485 Device Connect RS 485 Device through the port in the back of SSC 2000 You are able to install and control the camera DVR and mu...

Страница 6: ...licable to the Version 3 1 over Connect with SSC 2000 by using the RS 485 port on the back of SHR 4080 In case of connecting with Half Duplex Connect the Tx of SHR 4080 RS 485 port with the Tx of SSC 2000 Connect the Tx of SHR 4080 RS 485 port with the Tx of SSC 2000 In case of connecting with Full Duplex Connect the Tx of SHR 4080 RS 485 port with the Rx of SSC 2000 Connect the Tx of SHR 4080 RS ...

Страница 7: ...ifferent with the SSC 1000 in communication method 1 In case of connecting with Half Duplex Connect the Tx of SSC 2000 port with the Tx of another SSC 2000 Connect the Tx of SSC 2000 RS 485 port with the Tx of another SSC 2000 2 In case of connecting with Full Duplex Connect the Tx of SSC 2000 with the Rx of another SSC 2000 Connect the Tx of SSC 2000 with the Rx of another SSC 2000 Connect the Rx...

Страница 8: ...ess the touch panel key or move the joystick joy shuttle and then the screen before the sleep mode is displayed again Camera control Selecting a camera 1 Press CAM key The camera display part of the screen will be as follows 2 Enter the camera number 0 255 you want by using the number key and press ENTER Selecting a monitor This function is to choose a monitor displaying the image of the cam era 1...

Страница 9: ...on is to set the camera screen the user wants to call and monitor whenever he she wants to Maximum 128 screens can be preset 0 127 1 Move the camera to the position you want by using a joystick and camera lens key 2 Press SAVE 3 When a window appears as shown below enter the preset number you want to save and press ENTER PRESET DELETE This function is to delete the preset position 1 Press DELETE 2...

Страница 10: ...e camera number display part Move to the connected device When you press DVR 000 on the connection information screen DVR 000 will be selected and the screen will be changed into the DVR control mode When you press MUX 000 on the connection information screen MUX 000 will be selected and the screen will be changed into the MUX control mode Enter the number of the connected DVR 1 Press the DVR key ...

Страница 11: ...nnel selection 1 Press the CH ICON below on the DVR screen 2 A channel selection screen will appear as shown below 3 Select the channel you want 4 Press the EXIT ICON on the lower right to finish selecting and return to the DVR control screen DVR channel can be selected by using the number keys 0 9 of the keyboard DVR MENU Press the setup icon on the lower left to control the menu of the selected ...

Страница 12: ...ayed on the screen when you complete the log in process Press the item you want to control on the main menu Press the EXIT ICON in the main menu to return to the camera con trol mode If the CHECK PASSWORD item is set Off in the keyboard setup press the MENU button MAIN MENU screen will directly appear without the log in process If you press the menu button while the OPERATOR s LEVEL is the MANAGER...

Страница 13: ...ollows 4800 9600 19200 38400 Among these 4 kinds of BAUD RATE select one BAUD RATE DUPLEX You can set the duplex mode of system keyboard Press DUPLEX and then the following window pops up FULL DUPLEX HALF DUPLEX Select one of the two duplex Press the exit icon on the lower left to finish RS 485 COMMUNICATION SETUP control and return to the KEYBOARD SETUP screen RS 232 COMMUNICATION SETUP The defau...

Страница 14: ...will be displayed on the screen You have to start again from entering the operator s number CHECK PASSWORD If it is set On a window will appear to ask the operator no and password when you entering the Menu screen If it is set Off you can directly enter the Menu mode The system has been set On on shipment REGISTER NEW OPERATER This function is to add a new user of the keyboard New Operator No Ente...

Страница 15: ...system An informing message will appear if there is already data stored in the system keyboard Press OK to start downloading Press Cancel or the EXIT ICON to return to the KEYBOARD SETUP screen DOWNLOAD process screen A download process screen will appear as shown below when you press OK on the down load check screen A message will appear when downloading is completed CAMERA DATA UPLOAD This funct...

Страница 16: ...t a language among these languages Factory Default Setup Resets all of the menu values to the default value Press OK to start the default setting The system will start again when the FACTORY DEFAULT SETUP is completed Chapter 6 OPERATOR LEVEL There are 3 levels of user who can be registered as a user including Admin Manager Operator Admin is the highest level The range and limit to the usage of va...

Страница 17: ...VERSE PLAY REVERSE PLAY FF RW POWER DC12V 600mA POWER CONSUMPTION BELOW 3W DIMENSIONS WxHxD NET 490 x 197x 282 PACKAGE 496 x 206x 288 WEIGHT kg NET 1 36Kg PACKAGE 2 6Kg Chapter 8 Q A The system keyboard communication is not worked Check the RS 485 communication line Check the address setup of system keyboard Refer to RS 485 COMMUNICATION SETUP GB 12 of Chapter 5 Menu setting for the method of addr...

Страница 18: ...GB 18 ...

Отзывы: