![Samsung S3F80JB Скачать руководство пользователя страница 275](http://html.mh-extra.com/html/samsung/s3f80jb/s3f80jb_user-manual_340834275.webp)
S3F80JB
COMPARATOR
14-1
14
COMPARATOR
OVERVIEW
P2.4, P2.5, P2.6 and P2.7 can be used as analog input pins for a comparator. The reference voltage for the 4-
channel comparator can be supplied either internally or externally at P2.7. When an internal reference voltage is
used, four channels (P2.4–P2.7) are used for analog inputs and the internal reference voltage is varied in 16
levels. If an external reference voltage is input at P2.7, the other P2.4, P2.5 and 2.6 pins are used for analog
inputs.
When a conversion is completed, the result is saved in the comparison result register CMPREG (EAH, Set1,
Bank1, Read-only). The initial values of the CMPREG are undefined and the comparator operation is disabled by
a reset. The comparator module has the following components:
— Comparator
— Internal reference voltage generator (4-bit resolution)
— External reference voltage source at P2.7
— Comparator mode register (CMOD)
— Comparison result register (CMPREG)
— Comparison input selection register (CMPSEL)
Содержание S3F80JB
Страница 1: ...S3F80JB 8 BIT CMOS MICROCONTROLLERS USER S MANUAL Revision 1 1 ...
Страница 327: ...ELECTRICAL DATA 8MHz S3F80JB 18 14 NOTES ...
Страница 339: ...FLASH APPLICATION NOTES S3F80JB Programming By Tool ...
Страница 341: ...S3F80JB 2 This is only an example for setting Vdd This is SPW2 which is one of OPT MTP Writers ...
Страница 342: ...Important Note Subject Toggling phenomenon when serial writing programming on the S3F80JB ...