The op-code of a conditional jump always contains a 4-bit field called the condition code (cc). This specifies under
which conditions it is to execute the jump. For example, a conditional jump with the condition code for "equal"
after a compare operation only jumps if the two operands are equal. Condition codes are listed in Table 6-6.
The carry (C), zero (Z), sign (S), and overflow (V) flags are used to control the operation of conditional jump
instructions.
Table 6-6. Condition Codes
Binary Mnemonic
Description Flags
Set
0000 F
Always
false
–
1000 T
Always
true
–
0111
(note)
C
Carry
C = 1
1111
(note)
NC
No carry
C = 0
0110
(note)
Z Zero
Z
=
1
1110
(note)
NZ
Not zero
Z = 0
1101 PL
Plus
S
=
0
0101 MI
Minus
S
=
1
0100 OV Overflow
V
=
1
1100
NOV
No overflow
V = 0
0110
(note)
EQ Equal
Z
=
1
1110
(note)
NE
Not equal
Z = 0
1001
GE
Greater than or equal
(S XOR V) = 0
0001
LT
Less than
(S XOR V) = 1
1010
GT
Greater than
(Z OR (S XOR V)) = 0
0010
LE
Less than or equal
(Z OR (S XOR V)) = 1
1111
(note)
UGE
Unsigned greater than or equal
C = 0
0111
(note)
ULT
Unsigned less than
C = 1
1011
UGT
Unsigned greater than
(C = 0 AND Z = 0) = 1
0011
ULE
Unsigned less than or equal
(C OR Z) = 1
NOTES:
1.
It indicates condition codes that are related to two different mnemonics but which test the same flag. For
example, Z and EQ are both true if the zero flag (Z) is set, but after an ADD instruction, Z would probably be used;
after a CP instruction, however, EQ would probably be used.
2. For operations involving unsigned numbers, the special condition codes UGE, ULT, UGT, and ULE must be used.
Содержание S3F80JB
Страница 1: ...S3F80JB 8 BIT CMOS MICROCONTROLLERS USER S MANUAL Revision 1 1 ...
Страница 327: ...ELECTRICAL DATA 8MHz S3F80JB 18 14 NOTES ...
Страница 339: ...FLASH APPLICATION NOTES S3F80JB Programming By Tool ...
Страница 341: ...S3F80JB 2 This is only an example for setting Vdd This is SPW2 which is one of OPT MTP Writers ...
Страница 342: ...Important Note Subject Toggling phenomenon when serial writing programming on the S3F80JB ...