CONTROL REGISTERS
S3F80JB
4-40
SYM
— System Mode Register
DEH Set1 Bank0
Bit
Identifier
.7 .6 .5 .4 .3 .2 .1 .0
Reset Value
0 – – x x x 0 0
Read/Write
R/W – – R/W
R/W
R/W
R/W
R/W
Addressing Mode
Register addressing mode only
.7
Tri-State External Interface Control Bit
(1)
0
Normal operation (disable tri-state operation)
1
Set external interface lines to high impedance (enable tri-state operation)
.6 and .5
Not used for S3F80JB
(2)
.4 – .2
Fast Interrupt Level Selection Bits
(3)
0 0 0
IRQ0
0 0 1
IRQ1
0 1 0
IRQ2
0 1 1
IRQ3
1 0 0
IRQ4
1 0 1
IRQ5
1 1 0
IRQ6
1 1 1
IRQ7
.1
Fast Interrupt Enable Bit
(4)
0
Disable fast interrupt processing
1
Enable fast interrupt processing
.0
Global Interrupt Enable Bit
(5)
0
Disable global interrupt processing
1
Enable global interrupt processing
NOTES
:
1. Because an external interface is not implemented for the S3F80JB, SYM.7 must always be "0".
2. Although the SYM register is not used, SYM.5 should always be “0”. If you accidentally write a “1” to this bit during
normal operation, a system malfunction may occur.
3. You can select only one interrupt level at a time for fast interrupt processing.
4. Setting SYM.1 to "1" enables fast interrupt processing for the interrupt level currently selected by SYM.2–SYM.4.
5. Following a reset, you must enable global interrupt processing by executing an EI instruction (not by writing a "1"
to
SYM.0).
Содержание S3F80JB
Страница 1: ...S3F80JB 8 BIT CMOS MICROCONTROLLERS USER S MANUAL Revision 1 1 ...
Страница 327: ...ELECTRICAL DATA 8MHz S3F80JB 18 14 NOTES ...
Страница 339: ...FLASH APPLICATION NOTES S3F80JB Programming By Tool ...
Страница 341: ...S3F80JB 2 This is only an example for setting Vdd This is SPW2 which is one of OPT MTP Writers ...
Страница 342: ...Important Note Subject Toggling phenomenon when serial writing programming on the S3F80JB ...