4-7
IOM Board
has no selectable options and installs in the system main KSU (
). It provides two serial I/O ports. First, install the Modem board, if required (see above).
Then, line the IOM board up with the horizontal card slot above the universal slots and slide it in.
Press gently on the centre of the board’s front panel to seat it and secure the board with the two
screws.
SERIAL I/O PORTS ON IOM BOARD
Default RS-232C port: SIO2, SIO3
Debug: SIO1
Interface Cards
TRUNK B Card
) has no selectable options. Insert as many Trunk B cards as are needed
into any universal slots (
). Push firmly in the middle of both card ejectors on each card
to ensure that it is fully inserted into the backplane connector.
8TRK Card
This card (
) has no selectable options. Insert as many 8TRK cards as are needed
into any universal slots (
). Push firmly in the middle of both card ejectors on each card
to ensure that it is fully inserted into the backplane connector.
PRI and TEPRI Card
CAUTION: Do not insert the card with system power on. Switch the power OFF.
The TEPRI card (
) installs in slot 1, 2 or 3 of any cabinet. The card supports either E1
or ISDN PRI service. The first set of four LEDs on the front of the card provides the status of the
service (Sync, AIS, Loss and Layer 2 Active states). The second set of four LEDs on the front of
the card displays the type of service. The first TEPRI card installed is the primary source of
external clocking. The second TEPRI installed is the secondary source of external clocking.
Clock selection is first cabinet, left to right, then second cabinet, left to right. The primary and
secondary clock sources should be mounted in the bottom cabinet to ensure stable reception of
clocking from the primary and secondary sources.
There are two RJ-45 modular jacks on the face of the card. The top jack is labelled T1, but is the
socket to use for PRI. The PRI software supports ETSI ISDN only. The bottom RJ45 jack can be
used for E1 connections. The settings for E1 or PRI service are selected by a bank of DIP
switches as defined in the table below.
Содержание OfficeServ500
Страница 1: ...SAMSUNG OfficeServ Installation Guide EnterpriseIPSolutions ...
Страница 11: ...502mm 567mm 300mm 1506mm 1004mm FIGURE 1 1 OFFICESERV500 CABINET DIMENSIONS 1 2 Chapter 1 Site Requirements ...
Страница 16: ...FIGURES 2 1 TO 2 4 ...
Страница 18: ...MOUNTING SCREWS FRONT LEFT SIDE BOTTOM FIGURE 2 2 ATTACHING LEGS TO MAIN CABINET ...
Страница 19: ...Bracket Bracket Screws Bracket Bracket Screws Ground Bar FIGURE 2 3 SIDE COVER MOUNTING BRACKETS ...
Страница 20: ...Mounting Screw Holes Mounting Screw Holes FIGURE 2 4 SECURING CABINET IN RACK ...
Страница 25: ...FIGURES 3 1 TO 3 4 ...
Страница 27: ...FIGURE 2 4 Power Input Location FIGURE 3 2 POWER INPUT LOCATION ...
Страница 28: ...110 220V selection switch FIGURE 3 3 SETTING VOLTAGE ON PSU ...
Страница 43: ...FIGURES 4 1 TO 4 24 ...
Страница 48: ...P1 P3 U7 U4 U6 U11 U3 P2 U2 U8 U5 U9 U10 U11 FIGURE 4 5 ESM BOARD ...
Страница 49: ...Screw Locations FIGURE 4 6 MCP2 LCP2 CARD SCREW LOCATIONS ...
Страница 50: ...P1 P2 P3 P4 U1 U2 U4 U4 U13 D3 D4 D2 D1 K2 K1 K3 T3 T4 T2 T1 FIGURE 4 7 MISC BOARD ...
Страница 51: ...Screw Locations FIGURE 4 8 SCP2 CARD SCREW LOCATIONS ...
Страница 52: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 U8 FIGURE 4 9 SCM BOARD ...
Страница 53: ...P1 U7 U4 U5 P2 U2 U1 U6 U3 FIGURE 4 10 MFM BOARD ...
Страница 54: ...P2 U3 U4 P1 U1 U8 U5 U9 U2 FIGURE 4 11 RCM BOARD ...
Страница 55: ...U10 U9 U8 U5 U7 L1 L2 P1 P2 FIGURE 4 12 MODEM BOARD ...
Страница 60: ...EJECTOR TABS SCREWS FIGURE 4 17 TEPRI CARD SCREW LOCATIONS ...
Страница 64: ...FIGURE 4 21 SVMi 16 CARD SERIAL PORT RESET BUTTON VOICE PROCESSING MODULE DISK DRIVE ...
Страница 67: ...RAM ROM ROM ROM ROM RAM Clear J2 1F DSP JP1 A law u law FIGURE 4 24 VDIAL CARD ...
Страница 71: ...110 FUSES VOLTAGE SETTING FIGURE 5 1 FUSES ON PSU ...
Страница 74: ...FIGURES 6 1 TO 6 6 ...
Страница 75: ...FIGURE 6 1 MDF CONNECTIONS LOOP START LINE TO TRUNK B CARD ...
Страница 77: ...FIGURE 6 3 MDF CONNECTIONS AC15 CARD ...
Страница 78: ...FIGURE 6 4 MDF CONNECTIONS OFF PREMISES EXTENSION FROM SLI CARD ...
Страница 86: ...FIGURES 7 1 TO 7 8 ...
Страница 87: ...FIGURE 7 1a MDF CONNECTIONS DIGITAL KEYSET TO DLI CARD ...
Страница 88: ...FIGURE 7 1b MDF CONNECTIONS DIGITAL KEYSET TO 16DLI CARD ...
Страница 89: ...IP Phone LAN Ethernet OfficeServ500 Digital Phone MCP2 MGI2 3 16DLI FIGURE 7 2 IP PHONE CONNECTION ...
Страница 91: ...FIGURE 7 4 WALL MOUNTING A DCS EURO KEYSET ...
Страница 92: ...1 2 1 3 FIGURE 7 5 WALL MOUNTING AN iDCS SERIES KEYSET WITH BASE WEDGE ...
Страница 93: ...FIGURE 7 6a MDF CONNECTIONS ADD ON MODULE TO DLI CARD ...
Страница 94: ...FIGURE 7 6b MDF CONNECTIONS ADD ON MODULE TO 16DLI CARD ...
Страница 95: ...FIGURE 7 7a MDF CONNECTIONS SINGLE LINE TELEPHONE TO SLI CARD ...
Страница 96: ...FIGURE 7 7b MDF CONNECTIONS SINGLE LINE TELEPHONE TO 8SLI OR 8MWSLI CARD ...
Страница 97: ...FIGURE 7 7c MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16SLI CARD ...
Страница 98: ...FIGURE 7 7d MDF CONNECTIONS SINGLE LINE TELEPHONE TO 16MWSLI CARD ...
Страница 99: ...FIGURE 7 8a MDF CONNECTIONS DOOR PHONE AND DPIM TO DLI CARD ...
Страница 100: ...FIGURE 7 8b MDF CONNECTIONS DOOR PHONE AND DPIM TO 16DLI CARD ...
Страница 104: ...FIGURES 8 1 TO 8 6 ...
Страница 115: ...FIGURES 9 1 TO 9 2 ...
Страница 117: ...FIGURE 9 2 CONNECTING iDCS 28D AND 18D KEYSET DAUGHTERBOARDS ...
Страница 132: ...Samsung Telecoms U K Limited Brookside Business Park Greengate Middleton Manchester M24 1GS ...