OfficeServ 7100
INSTALLATION
TECHNICAL MANUAL
PART 3 JULY 2010
3.5
(reset) switch for 7 to 10 seconds. To default the system programming during boot up
sequence wait for 3 minutes and then press and hold the RST (reset switch). When the
boot up sequence is complete the system’s database will be defaulted.
Note: The S2 dip switches are set properly by the factory for a 3-digit numbering plan and
the country of USA. These dip switches should be left at default and should never be
changed. If a 4-digit numbering plan is required, the numbering plan should be changed
in the software by using MMC 724.
DIP SWITCH USE (S2)
ON (left) OFF (right)
4 DIGIT STATION NUMBERS
SW8
3 DIGIT STATION NUMBERS
4 DIGIT STATION GROUPS
SW7
3 DIGIT STATION GROUPS
4 DIGIT TRUNK NUMBERS
SW6
3 DIGIT TRUNK NUMBERS
RESERVED
SW5
RESERVED
COUNTRY SELECT
SW4
COUNTRY SELECT
COUNTRY SELECT
SW3
COUNTRY SELECT
COUNTRY SELECT
SW2
COUNTRY SELECT
COUNTRY SELECT
SW1
COUNTRY SELECT
•
Switches 1 through 4 select the country the system is installed in.
4
3
2
1
Country
OFF
OFF
OFF
OFF
Korea
OFF
OFF
OFF
ON
USA
OFF
OFF
ON
OFF
UK
OFF
OFF
ON
ON
Italy
OFF
ON
OFF
OFF
Australia
OFF
ON
OFF
ON
New Zealand
OFF
ON
ON
OFF
Holland
OFF
ON
ON
ON
Denmark
Switch 5 is reserved.
These DIP switches will not take effect unless the switches are set in the wanted position
and the system memory is cleared manually by using the Memory Backup switch.
3.2.2 Installing Optional Daughtercards on the MP10/MP10a
Three (3) types of optional daughtercards can be installed on the MP10/MP10a:
1)
Optional modem daughtercard (installed in the connector located towards the back of the
MP10/MP10a)
2)
The optional 4SWM PoE LAN daughtercard (installed in the connector located towards the
front of the MP10/MP10a)
Home Page
Table of Contents
Home Page
Table of Contents