OfficeServ 7030 Installation Manual

3)  Fasten the cables to the cabinet with a cable tie.

Figure 2.17  Cabling

© SAMSUNG Electronics Co., Ltd.

13

Содержание OfficeServ 7030

Страница 1: ...Ed 01 OfficeServ 7030 Installation Manual ...

Страница 2: ...cial purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics Co Ltd TRADEMARKS is the trademark of SAMSUNG Electronics Co Ltd Product names mentioned in this manual may be trademarks and or registered trademarks of their respective companies This manual should be read and used as a guideline for properly installing and operating the product ...

Страница 3: ...ave any questions concerning the contents of the manuals contact our Document Center at the following address or Web site Address Document Center 2nd Floor Jeong bo tong sin dong Dong Suwon P O Box 105 416 Maetan 3dong Yeongtong gu Suwon si Gyeonggi do Korea 442 600 Homepage http www samsungdocs com 2008 SAMSUNG Electronics Co Ltd All rights reserved ...

Страница 4: ......

Страница 5: ......

Страница 6: ...n site grounding power conditions etc which should be inspected before installing the OfficeServ 7030 system This chapter also describes the items included in the OfficeServ 7030 package and the installation procedure CHAPTER 2 Mounting and Replacing the Boards This chapter describes how to mount replace various boards to from the OfficeServ 7030 system CHAPTER 3 Installing the System This chapter...

Страница 7: ...INTRODUCTION This chapter describes how to connect the C O lines to the OfficeServ 7030 system II SAMSUNG Electronics Co Ltd ...

Страница 8: ...ION Describes the abbreviations frequently used in this document Conventions The following types of paragraphs contain special information that must be carefully read and thoroughly understood Such information may or may not be enclosed in a rectangular box separating it from the main text but is always preceded by an icon and or a bold title WARNING Provides information or instructions that the r...

Страница 9: ...INTRODUCTION Indicates additional information as a reference IV SAMSUNG Electronics Co Ltd ...

Страница 10: ...ircuit configuration and feature of the system OfficeServ 7030 Programming Manual This manual describes how to use the MMC program to change the setting of the OfficeServ 7030 system from the phone Revision History EDITION DATE OF ISSUE REMARKS 00 06 2008 First Draft 01 07 2008 Functions of BRI MEM LAN LED are changed Cautions are added Turning off power switch after dismounting MEM Checking MEM L...

Страница 11: ...INTRODUCTION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Страница 12: ...formation must be given to the operator user and shall be read before the installation and operation Symbols Caution Indication of a general caution Restriction Indication for prohibiting an action for a product Instruction Indication for commanding a specifically required action SAMSUNG Electronics Co Ltd VII ...

Страница 13: ...round outlet The GND in the back panel of the OfficeServ 7030 system should be grounded Using double pole neutral fusing Do not attempt to repair the system after only removing the fuse from the neutral line doing so may cause electric shock If the repair is required unplug the system s power cord before proceeding AC power connection restriction Connect the system s AC power to a separated AC out...

Страница 14: ...Manual Caution for power supply when mounting the board Check if the cabinet power is turned off when mounting the board Inserting or removing a board while the power is turned on may damage the board SAMSUNG Electronics Co Ltd IX ...

Страница 15: ...ize of the supplementary equipment grounding conductor should not be smaller than the ungrounded branch circuit supply conductors The supplementary equipment grounding conductor should be connected to the product from the provided terminal and connected to the earth in order to maintain the earth connection when the power supply cord is unplugged The connection of the supplementary grounding condu...

Страница 16: ... covered or insulated conductor must have a uniform outer finish either green or green with yellow stripes Separation of TNV and SELV Pluggable A The separate protective grounding terminal provided with this product should be permanently connected to the earth Instruction SAMSUNG Electronics Co Ltd XI ...

Страница 17: ...king MEM LED before power off Don t turn off the power during blinking MEM LED It may cause malfunction of system If you want to turn off power turn off power switch after dismounting MEM with Key MMC 817 MEM UMOUNT Checking power off Check if the cabinet power is turned off when mounting the board Inserting or removing a board while the power is turned on may damage the board Board reset New sett...

Страница 18: ...rv 7030 Installation Manual Turning off power switch after dismounting MEM You should dismount MEM before turning off power switch Use Key MMC 817 MEM UMOUNT when dismounting MEM SAMSUNG Electronics Co Ltd XIII ...

Страница 19: ... Check if LAN cable is connected during lighting LAN LED on Caution for using extension cable Check if extension cable is connected during operation The expansion cabinet may malfunction if extension cable is not connected during operation In that case you should connect extension cable again and restart expansion cabinet XIV SAMSUNG Electronics Co Ltd ...

Страница 20: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd XV This page is intentionally left blank ...

Страница 21: ...umidity Conditions 1 1 2 Grounding Conditions 3 1 3 Power Conditions 3 1 4 Checking the Package 5 1 5 Cabinet Configuration 6 1 6 System Installation Procedure 10 CHAPTER 2 Mounting and Replacing the Boards 1 2 1 Connecting the Grounding Wire 1 2 1 1 Opening 1 2 1 2 Grounding 4 2 2 Mounting the Boards 5 2 2 1 Removing Dummy Parts 5 2 2 2 Setting Switches 5 2 2 3 Mounting Optional Boards 7 2 2 4 Mo...

Страница 22: ... Conditions 1 5 2 Connecting the C O Line 2 5 2 1 Cautions When Connecting the C O Line 2 5 2 2 Connecting Common C O Line 2 CHAPTER 6 Connecting the Stations and Additional Equipment 1 6 1 Connecting the Stations 1 6 1 1 Cautions when Connecting the Stations 1 6 1 2 Connecting Analog Phones 2 6 1 3 Connecting Digital Phones 3 6 1 4 Connecting IP Phones 5 6 1 5 Connecting to a Door Phone and Door ...

Страница 23: ...vironment 1 7 1 2 Safety Conditions 2 7 2 Starting the System 2 7 3 Numbering Extensions and C O Lines 3 7 4 Checking the System s Operation 4 7 4 1 Station Call Function 4 7 4 2 Station Camp On Function 4 7 4 3 C O Line Call Function 6 7 4 4 C O Line Camp On Function 6 2 I 4 I A I B I D I G II I II L III M III P III S III T III U III XVIII SAMSUNG Electronics Co Ltd ...

Страница 24: ...ng the top cover 3 Figure 2 5 Grounding 4 Figure 2 6 Removing the dummy parts 5 Figure 2 7 Setting the Base Board Switches 6 Figure 2 8 Mounting a MODEM Board on the Base Board 7 Figure 2 9 Mounting an EPM Board on the Base Board 7 Figure 2 10 Setting Switches on the EPM Board 8 Figure 2 11 Location of the Base Board Slots 9 Figure 2 12 Mounting 2BM 4TM on the Base Board 10 Figure 2 13 Mounting 2D...

Страница 25: ...allation on a Wall 1 Figure 3 2 Installation on a Wall 1 2 Figure 3 3 Installation on a Wall 2 2 Figure 3 4 Installation on a Wall 3 2 Figure 3 5 Installation on a Wall 4 4 Figure 3 6 Extension cable 4 Figure 3 7 Connecting the basic cabinet to the expansion cabinet 6 Figure 4 1 Connecting the Power use of a cabinet 2 Figure 4 2 Connecting the Power using Power cable 3 Figure 4 3 Connecting an Ext...

Страница 26: ...rd 3 Figure 6 5 IP Digital Phone Layout 5 Figure 6 6 RJ 45 Port of the Ethernet Connection Board 6 Figure 6 7 RJ 45 Port of the 4DM 2DM Boards for Door Phone 6 Figure 6 8 Connecting MOH BGM Sources 9 Figure 6 9 Connecting External Additional Page Equipment 10 Figure 6 10 Connecting Common Bells 11 Figure 6 11 Connecting Installation Tool 13 Figure 6 12 Installation Tool 14 Figure 6 13 Web Manageme...

Страница 27: ...9 Table 2 1 Jumpers Switches of the Base EPM Board 5 Table 2 2 Base Board Switches 6 Table 2 3 EPM board switches 8 Table 2 4 Mountable Boards 9 Table 5 1 Line condition of the OfficeServ 7030 1 Table 6 1 Distance Between Stations and the System 1 Table 6 2 Specification for the Wireless LAN Connection 8 Table 6 3 Specifications for the PC for Programming 12 Table 6 4 Specification of the SMDR Sys...

Страница 28: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd XXIII This page is intentionally left blank ...

Страница 29: ...able objects OfficeServ 7030 system should not be installed near equipments that generate electromagnetic waves such as monitors or copying machines The installation location should be easily accessible for trunk line and extension line deployment for power and grounding wire connection and for maintenance and repair OfficeServ 7030 system should not be installed in populated aisles passageways or...

Страница 30: ... 1 Before Installing Operation Temperature 0 40 C Storage temperature 10 50 C Humidity 10 90 Cool area protected from direct sunlight Ventilators should be installed to remove dust 2 SAMSUNG Electronics Co Ltd ...

Страница 31: ...ing installation should comply with the local standard all related works should be conducted according to the local standard External grounding is required to prevent bodily injuries or system damages from lightning static electricity or voltage surge Unplug the AC power cord before connecting the ground cable Failure to do so may cause bodily injury The OfficeServ 7030 system should be connected ...

Страница 32: ...CHAPTER 1 Before Installing Output Power DC 54 V 0 5 A DC 5 V 3 A DC 12 V 1 8 A 4 SAMSUNG Electronics Co Ltd ...

Страница 33: ...able 1 Template Wall Mount Template 1 Guide Open closing Guide 1 Bushing Wall mount Bushing 4 Screw Wall mount Screw 4 Lug Lug for connecting FGND 1 Manual Installation Manual Optional UTP Cable Types Two types of UTP cable are available Straight through UTP cable and Crossover UTP cable The Straight through UTP cable is used to connect the OfficeServ 7030 system s 4LM module to another system SAM...

Страница 34: ...ed on the left of the cabinet are listed in the table below Table 1 3 Parts on the left side of the cabinet Part Function Power Switch Turns the power of the OfficeServ 7030 system on off Power I O Connector Connector for the power cable connection Turning off power switch after dismounting MEM You should dismount MEM before turning off power switch Use Key MMC 817 MEM UMOUNT when dismounting MEM ...

Страница 35: ...below Table 1 4 Parts on the top side of the cabinet Part Function RUN LED Main CPU operation status Off Idle On Green Booting Blink Green Normal Operation of the Program ON Red Clearing the Flash Memory Database LAN LED LAN operation status Off LAN is not connected On Green LAN is connected EPM is connected Blink Green Tx Rx of data through LAN port SAMSUNG Electronics Co Ltd 7 ...

Страница 36: ...cognizing Flash memory On Green After recognizing Flash memory and normal state of the Flash memory Blink Green Accessed by application and Read Write Erase BRI LED The port status Off Not used On Green In use Blink Green BRI line is activated 8 SAMSUNG Electronics Co Ltd ...

Страница 37: ...d during lighting LAN LED on Figure 1 3 Right Side View of the OfficeServ 7030 Cabinet The descriptions of each part located on the right of the cabinet are listed in the table below Table 1 5 Parts on the right panel of the cabinet Part Function C O 1 4 Trunk ports LINK1 3 Ports that connect the base cabinet with the expansion cabinet EXT1 8 Station ports for subscribers i e analog phone digital ...

Страница 38: ...e the cabinet s dummy parts to insert the daughter boards 4 Insert the daughter boards into the universal slots slot 2 3 and 4 5 Install the cabinet on a wall if necessary depending on the installation environment 6 Connect and tie the cables with the cable ties 7 Connect the AC 200 240 V input power If necessary connect Uninterruptible Power Supply UPS 10 SAMSUNG Electronics Co Ltd ...

Страница 39: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd 11 This page is intentionally left blank ...

Страница 40: ...rom the OfficeServ 7030 system 2 1 Connecting the Grounding Wire This section describes how to open the cabinet and connect an external grounding wire to the OfficeServ 7030 system 2 1 1 Opening 1 Hold the cable duct cover and push upward as shown in the following picture Figure 2 1 Removing the cable duct cover 1 SAMSUNG Electronics Co Ltd 1 ...

Страница 41: ...eplacing the Boards 2 Separate the cable duct cover Figure 2 2 Removing the cable duct cover 2 3 Remove the two screws Figure 2 3 Removing the screws 4 Push and lift the top cover to open the case 2 SAMSUNG Electronics Co Ltd ...

Страница 42: ...OfficeServ 7030 Installation Manual Figure 2 4 Removing the top cover SAMSUNG Electronics Co Ltd 3 ...

Страница 43: ...area of 0 8mm2 The nominal thread diameter of the screw should be at least 3 5 mm a UL Listed Lug Terminal should be used for the ring terminal Connect the grounding to the base board as shown in the figure below Tighten the ground cable to the base board with a screw Figure 2 5 Grounding Checking external grounding After installing the OfficeServ 7030 system ensure that the GND in the inner side ...

Страница 44: ...ure 2 6 Removing the dummy parts 2 2 2 Setting Switches The base board and EPM board that are equipped with switches relative to the user requirements system configuration and or daughter boards are as follows Table 2 1 Jumpers Switches of the Base EPM Board Board Switch Description Base S1 1 8 Sets the country code and future use EPM S1 1 2 Sets whether to use the 4LM daughter board and whether t...

Страница 45: ...ows Set the base board s S1 switch from SW5 to SW8 to Off SW1 to SW4 are set depending on the user s purpose Figure 2 7 Setting the Base Board Switches Table 2 2 Base Board Switches Switch Description S1 SW1 SW4 The pins set the system s country code SW5 Reserved for future use SW6 IP address Setting On Default factory setting address Off User setting address SW7 SW8 Reserved for future use 6 SAMS...

Страница 46: ...oard EPM or MODEM connectors and press the optional board firmly downward with two hands 1 Mount the MODEM board to the base board s P7 and P8 connectors Figure 2 8 Mounting a MODEM Board on the Base Board 2 Mount the EPM board to the base board s P2 connector Figure 2 9 Mounting an EPM Board on the Base Board SAMSUNG Electronics Co Ltd 7 MODEM EPM ...

Страница 47: ...hten the screw Tighten the screws which fit within the grooves of the EPM boards Figure 2 10 Setting Switches on the EPM Board Table 2 3 EPM board switches Switch Description S1 SW1 ON Master cabinet Off Slave cabinet SW2 ON Standalone Off Master and slave 8 SAMSUNG Electronics Co Ltd S1 OFF ON ...

Страница 48: ...BM Subscriber Part Slot 2 and Slot 3 4DM 2DM 4SM 4LM Figure 2 11 Location of the Base Board Slots The 4TM Module board does not support the Dial Pulse dialing but it supports the DTMF dialing Caution for the power supply when mounting the boards Check if the cabinet power is turned off when mounting the board Inserting or removing a board while the power is turned on may damage the board or cause ...

Страница 49: ...M can be mounted to the base board s P3 connector Figure 2 12 Mounting 2BM 4TM on the Base Board 2 2DM 4DM 4SM or 4LM can be mounted to the base board s P1 and P4 connector Figure 2 13 Mounting 2DM 4DM 4SM 4LM on the Base Board 10 SAMSUNG Electronics Co Ltd ...

Страница 50: ...OfficeServ 7030 Installation Manual 3 Tighten the screws which fit within the grooves of the daughter boards Figure 2 14 Tightening screws to install the daughter boards SAMSUNG Electronics Co Ltd 11 ...

Страница 51: ...the Boards 2 2 5 Closing Cabling 1 Push and align the top cover to close the case Figure 2 15 Installing the top cover 1 2 Tighten two screws to install the top cover Figure 2 16 Installing the top cover 2 12 SAMSUNG Electronics Co Ltd ...

Страница 52: ...OfficeServ 7030 Installation Manual 3 Fasten the cables to the cabinet with a cable tie Figure 2 17 Cabling SAMSUNG Electronics Co Ltd 13 ...

Страница 53: ...s 4 Align and install the cable duct cover as follows Figure 2 18 Installing the duct cover 1 5 Hold the cable duct cover and push downward as shown in the following picture Figure 2 19 Installing the duct cover 2 14 SAMSUNG Electronics Co Ltd ...

Страница 54: ...se board or daughter board replace the board with a new one Removing the Cables Before replacing a daughter board remove all cables connected to the board To replace a board mounted in the slot of a cabinet proceed as follows 1 Turn off the power of the cabinet in which the board is mounted Figure 2 20 Turning Off the Cabinet Power SAMSUNG Electronics Co Ltd 15 ...

Страница 55: ...CHAPTER 2 Mounting and Replacing the Boards 2 Remove the cable duct cover and open the upper case Refer to section 2 1 1 Opening 16 SAMSUNG Electronics Co Ltd ...

Страница 56: ...gure 2 21 Removing the boards 4 Align the new board to the connector of the slot and press the daughter boards firmly downward with two hands Tighten the screw Figure 2 22 Replacing the daughter boards 5 Close the cabinet Refer to section 2 2 5 Closing Cabling SAMSUNG Electronics Co Ltd 17 ...

Страница 57: ...g on the installation environment 3 1 Installing on a Wall This section describes how to install the OfficeServ 7030 cabinet on a wall 3 1 1 Required Tools Mid sized Phillips screw driver Electric drill Hammer Wall Mount Template Four plastic Bushings Four cross type screws Figure 3 1 Required Tools for the Installation on a Wall SAMSUNG Electronics Co Ltd 1 ...

Страница 58: ...mm depth and approx 6 mm width to ease the insertion of the plastic bushings Figure 3 2 Installation on a Wall 1 2 Fix plastic anchors into the drilled holes with a hammer Figure 3 3 Installation on a Wall 2 3 Align the screw holes of the wall type bracket to the fixed plastic anchors positions Insert the screws to each hole and tighten the screws with a Philips screw driver Figure 3 4 Installatio...

Страница 59: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd 3 ...

Страница 60: ...the OfficeServ 7030 system consists of a basic cabinet and an expansion cabinet connect the Base cabinet to the expansion cabinet using the extension cables to allow signal transmissions between the base boards 1 Three extension cables are needed to connect the Basic cabinet to the expansion cabinet Figure 3 6 Extension cable 2 With an extension cable connect the basic cabinet s Link1 port to the ...

Страница 61: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd 5 ...

Страница 62: ...et Do not put the expansion cabinet on top of basic cabinet horizontally Doing so may cause a system failure or fire due to rising internal heat of the basic cabinet Caution for using extension cable Check if extension cable is connected during operation The expansion cabinet may malfunction if extension cable is not connected during operation In that case you should connect extension cable again ...

Страница 63: ... If the input power is interrupted the system can be operated using the external UPS When connecting the power to the OfficeServ 7030 system pay attention to the following criteria The system supports 200 240 V AC power A single AC outlet should be used solely for the system s AC power Sharing the AC power with other devices can cause static and or voltage drop resulting in system malfunction or f...

Страница 64: ... cabinet configuration Use the power cable provided with the OfficeServ 7030 system to connect the input power terminal located on the right panel of the basic cabinet to a grounded outlet Figure 4 1 Connecting the Power use of a cabinet 2 SAMSUNG Electronics Co Ltd ...

Страница 65: ...7030 Installation Manual Basic and Expansion Cabinet Configuration Connect each input power cable of the cabinet to a grounded outlet Figure 4 2 Connecting the Power using Power cable SAMSUNG Electronics Co Ltd 3 ...

Страница 66: ...tem in case of a power failure The rated capacity of an external UPS is AC 200 240 V per cabinet The UPS should be connected to each cabinet to guarantee safety To connect an external UPS to the OfficeServ 7030 system proceed as follows 1 Prepare the UPS provided with the product 2 Connect each cabinet Figure 4 3 Connecting an External UPS 4 SAMSUNG Electronics Co Ltd UPS ...

Страница 67: ...by connecting the C O lines to the extensions If a pair of trunk lines 4TM is connected to Pin1 and Pin2 of the first port in the base board s SLI the lines will be connected to a phone through Pin 4 and 5 of the 4TM During the power failure emergency calls can be available since the C O line is directly connected to the phone by the internal relay operation Figure 4 4 Connecting the Power Fail Tr...

Страница 68: ...CHAPTER 4 Connecting the Power 6 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...

Страница 69: ...remove the moisture before wiring The cables should be handled carefully to prevent any distortions or damages The subscriber lines should be kept indoors if at all possible Do not cable the subscriber lines around any high voltage power line The leak resistance of the C O line connected to the OfficeServ 7030 system is as follows Table 5 1 Line condition of the OfficeServ 7030 Line Condition Leak...

Страница 70: ... conditions such as storm and lightning Do not connect the C O line in humid areas 5 2 2 Connecting Common C O Line Use a pair of AWG 24 or AWG 26 cable to connect a common C O line to the terminal pin of a terminal box connected to the OfficeServ 7030 system equipped with a 4TM or 2BM board Connecting to the 4TM Board Pin No 1 2 3 4 5 6 7 8 Function PFT TIP PFT RING C O TIP C O RING Figure 5 1 P1...

Страница 71: ...OfficeServ 7030 Installation Manual Figure 5 2 P2 P4 RJ 45 Port of the 4TM Board SAMSUNG Electronics Co Ltd 3 ...

Страница 72: ...CHAPTER 5 Connecting the C O Line Connecting to the 2BM Board Pin No 1 2 3 4 5 6 7 8 Function TX RX RX TX Figure 5 3 RJ 45 Port T Mode only of the 2BM Board 4 SAMSUNG Electronics Co Ltd P1 P2 Port RJ 45 ...

Страница 73: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd 5 This page is intentionally left blank ...

Страница 74: ...ns in extreme weather conditions such as storm and lightning Do not connect the stations in humid areas Comply with the manual of the station as well as with this document when reconnecting the stations or changing the connections Connect the stations with a pair of 24 AWG or 26 AWG cables The distances between the stations and the OfficeServ 7030 system are as follows Table 6 1 Distance Between S...

Страница 75: ...onnecting to the Base Board s SLT Connect an analog phone to the ports of the base board s SLT with a pair of AWG 24 or AWG 26 cables Pin No 1 2 3 4 5 6 7 8 Function PFT TIP PFT RING SLI TIP SLI RING Figure 6 1 SLT1 RJ 45 Port of the Base Board Pin No 1 2 3 4 5 6 7 8 Function SLI TIP SLI RING Figure 6 2 SLT2 RJ 45 Port of the Base Board 2 SAMSUNG Electronics Co Ltd SLT1 Port RJ 45 SLT2 Port RJ 45 ...

Страница 76: ... phone to the base board s 4DM Connecting to the 4DM Board Connect a digital phone to the ports of the base board s 4DM with a pair of AWG 24 or AWG 26 cables Pin No 1 2 3 4 5 6 7 8 Function DLI TIP DLI RING Figure 6 4 P1 P4 RJ 45 Port of the 4DM Board Maximum number of allowed DS 5012L phones Up to one DS 5012L phone can be connected to each 4DM board of the OfficeServ 7030 system If more than on...

Страница 77: ...itional Equipment 4DM board the power supply for all digital phones connected to the same board will be automatically blocked Up to two DS 5012L phones can be connected to the basic cabinet or the expansion cabinet 4 SAMSUNG Electronics Co Ltd ...

Страница 78: ...data to PCM voice data and transmits the data to the base board through the 4DM board 3 The PCM voice data is converted to packet data by the base board and transferred to the IP phone 4 The IP phone converts the packet voice data to analog voice signals and displays the signals through a handset or speaker 5 The Voice signals coming from the IP phone are converted to packet data and transmitted t...

Страница 79: ...r Phone Interface Module DPIM Connect a pair of 24 AWG or 26 AWG cables to the LINE port of the DPIM and the ports of the OfficeServ 7030 system s 4DM board Connecting to the 4DM 2DM Boards Pin No 1 2 3 4 5 6 7 8 Function DLI TIP DLI RING Figure 6 7 RJ 45 Port of the 4DM 2DM Boards for Door Phone 1 Connect the Door port of the DPIM and the line port of the DOOR BOX 2 When using an automatic door l...

Страница 80: ...OfficeServ 7030 Installation Manual with a 12 VDC 100 mA current SAMSUNG Electronics Co Ltd 7 ...

Страница 81: ...IP phone Table 6 2 Specification for the Wireless LAN Connection Item OfficeServ 7030 System Basic Cabinet Maximum number of users 16 Number of simultaneous users MMC845 setting For information on how to install and use the SMT R2000 and SMT W5100 refer to the VoWLAN Administration Guide Connect the 4LM board and the SMT R2000 WAN port with a RJ 45 Ethernet cable maximum distance 100m The SMT R200...

Страница 82: ...O or extension line music sources The selection of internal external music sources is performed through the MMC 861 One external music source is provided while on hold the external music source is connected to the MISC port A pair of MOH BGM source lines is connected to Pin4 and Pin5 of the base board s MISC port Figure 6 8 Connecting MOH BGM Sources MMC Select music sources for the C O lines thro...

Страница 83: ... of External Page Equipment lines is connected to Pin3 and Pin6 the Dry Contact 1 line is connected to Pin1 and Pin2 and the Dry Contact 2 line is connected to Pin7 and Pin8 of the base board s MISC port Figure 6 9 Connecting External Additional Page Equipment Dry Contact A Dry Contact is a switch that can establish or release a power line connection of an external equipment 6 2 3 Connecting Commo...

Страница 84: ...OfficeServ 7030 Installation Manual Figure 6 10 Connecting Common Bells SAMSUNG Electronics Co Ltd 11 ...

Страница 85: ...llation Tool when you need to install a new system component or change a system component or modify the database Below are the specifications required for the PC for programming where the Installation Tool is to be installed Table 6 3 Specifications for the PC for Programming Item Specification PC CPU Pentium III or faster Main Memory 256 MBytes or more HDD Drive At least 30 MBytes of free space O...

Страница 86: ...e software to use that PC If a LAN is configured in your company connect it to the LAN port of the Base board and the PC for programming to it If no LAN is configured in your company connect the PC for programming to the LAN port of the 4LM Base board Figure 6 11 Connecting Installation Tool Below are the steps for connecting a PC for programming to the system 1 Configure the network parameters us...

Страница 87: ...tem 2 Set the subnet mask of the OfficeServ 7030 system 3 Set the gateway IP address of the OfficeServ 7030 system 4 Reset the board Resetting the Board You have the reset to board to apply the new settings If the board is not reset correctly it may cause product malfunction Configuring the Installation Tool parameters 1 Run the Installation Tool 2 On the main screen of the Installation Tool selec...

Страница 88: ...OfficeServ 7030 Installation Manual 3 When the Link Control is displayed enter the name of the system in the Name field SAMSUNG Electronics Co Ltd 15 ...

Страница 89: ...7030 system in the IPAddress field If the Link Type is MODEM enter the internal modem number of the OfficeServ 7030 system in the Telephone field Caution for Connecting Modem One of external modems produced at following companies should be used to connect OfficeServ 7030 U S Robotics Hayes Zoom 16 SAMSUNG Electronics Co Ltd ...

Страница 90: ...n an in house network connect LAN to the LAN port of the base board and try accessing from a client PC Setting the Network parameter through the MMC830 program Set the network parameter of the OfficeServ 7030 system For the setting value of the network parameter contact the network administrator 1 Set the IP address of the OfficeServ 7030 system 2 Set the subnet mask of the OfficeServ 7030 system ...

Страница 91: ...cute your browser Internet Explorer 5 5 or higher 2 Access the Web Management through the LAN IP address Access address https System LAN IP Address Figure 6 13 Web Management Initial Screen 3 Enter your ID and password on the Web Management initial screen and click the OK button to log in 18 SAMSUNG Electronics Co Ltd ...

Страница 92: ...AN port of the 4LM board or the base board built in the OfficeServ 7030 system The SMDR system specification is as follows Table 6 4 Specification of the SMDR System Item Specification Platform IBM PC CPU Pentium 586 or higher Operating System Windows 95 98 or later Main Memory 32 MByte or more To use within the company s LAN network connect LAN to the LAN port of the Base board and connect a SMDR...

Страница 93: ...me whenever an event occurs To use within the company s LAN network connect LAN to the LAN port of the Base board and connect a printer to the LAN If the 4LM is built in the Base board a printer can be connected to the LAN port of the 4LM Figure 6 15 Connecting Printers MMC After connecting a printer execute the MMC 804 and enter the I O port through which the printer is connected 20 SAMSUNG Elect...

Страница 94: ...ure Check if the room temperature is between 0 C and 40o C If the room temperature is above or below the operational temperature install a heating cooling device to maintain the operational temperature Humidity Check if the humidity of the room is between 10 and 90 Take special caution since the humidity affects the electric components and the connectors of the system Direct Sunlight and Dust The ...

Страница 95: ...ltage switch of the PSU is properly set according to the voltage of the input power 200 240 VAC Check if the grounding terminal on the rear panel of the system is properly connected to the external grounding 7 2 Starting the System To start the OfficeServ 7030 system proceed as follows 1 Check if the boards and cables are properly mounted and connected to the OfficeServ 7030 cabinet 2 Turn on the ...

Страница 96: ...igned to the extension board mounted on Slot 1 of the basic cabinet and the subsequent numbers are respectively assigned to the next extension board of the next slot This numbering process continues until the extension numbers are assigned to all extensions However only the numbers from 201 to 349 are assigned when using 3 digits By default the first port of the first 4DM board is assigned to the ...

Страница 97: ...nt answers the call check the call status 5 Hang up the phone and call a busy station Verify the busy tone 7 4 2 Station Camp On Function If a caller dials a number and the recipient is busy this function automatically connects the recipient and the caller right after the recipient hangs up the call Follow the procedure below and check the Station Camp On function 1 Lift the handset of the test ph...

Страница 98: ...Manual Check if the other phone rings 6 Lift the handset of the other phone Check if the other phone stops ringing if the ring back tone of the test phone stops and if the parties are normally connected SAMSUNG Electronics Co Ltd 5 ...

Страница 99: ...sy this function reserves a C O line and notifies the caller if the C O line becomes available Follow the procedure below and check the C O Line Camp On function 1 Lift the handset of the test phone and press a C O line code Verify the C O line dial tone 2 Check if a busy tone rings when all C O lines are busy 3 Upon verifying the busy tone press the hook flash switch of the test phone Check if th...

Страница 100: ...OfficeServ 7030 Installation Manual SAMSUNG Electronics Co Ltd 7 This page is intentionally left blank ...

Страница 101: ...M 2 port BRI Module 4 4DM 4 port DLI Module 4LM 4 port LAN Module 4SM 4 port SLI Module 4TM 4 port Trunk Module A AC Alternating Current AFT Automatic Function Test AP Access Point AWG American Wire Gauge B BGM Background Music D DC Direct Current SAMSUNG Electronics Co Ltd I ...

Страница 102: ...ABBREVIATION DLI Digital Line Interface DPIM Door Phone Interface Module DSL Digital Subscriber Line G GND Ground I IP Internet Protocol II SAMSUNG Electronics Co Ltd ...

Страница 103: ...itting Diode M MOH Music on Hold MGI P PCM Pulse Code Modulation PSU Power Supply Unit S SLI Single Line Interface SMDR Station Message Detail Recording T TEPRI2 T1E1PRI TRK Trunk UTP Unshielded Twisted Pair U UPS Uninterruptible Power Supply UTP Unshielded Twisted Pair SAMSUNG Electronics Co Ltd III ...

Страница 104: ...ABBREVIATION IV SAMSUNG Electronics Co Ltd ...

Страница 105: ...reserved Information in this manual is proprietary to SAMSUNG Electronics Co Ltd No information contained here may be copied translated transcribed or duplicated by any form without the prior written consent of SAMSUNG Information in this manual is subject to change without notice ...

Отзывы: