4. Troubleshooting
► Error Code
S7–2110
► Error message
Fuser Failure: #S7-2110. Turn off then on
► Symptom
Abnormal heater control has been detected by the Main Board. Therefore, the Main Board has turned Main Relay "Off".
► Troubleshooting method
1) Turn the machine off. Re-install the fuser unit, then turn the machine on.
2) If the problem persists, turn the machine off.
3) Replace the fuser drive board.
4) If the problem persists, replace the main board.
4-180
Copyright© 1995-2016 SAMSUNG. All rights reserved.
Содержание MultiXpress M4370 Series
Страница 58: ...2 Product Specifications and Description M4370 2 44 Copyright 1995 2016 SAMSUNG All rights reserved ...
Страница 201: ...4 Troubleshooting 6 Close the right bottom door Copyright 1995 2016 SAMSUNG All rights reserved 4 23 ...